Ingenieurwerkzeug · Abwasserreinigung
Belebtschlamm-Auslegung
Legen Sie konventionellen Kohlenstoffabbau mit Belebtschlamm und optionaler Nitrifikation über einen nachvollziehbaren biologischen Rechenkern aus.
Process basis
Project / design basis
Influent / effluent basis
BOD5 and COD remain separate measured bases.
The entered BOD5 influent and target values are the selected biological design basis. The model does not predict downstream clarification-related particulate BOD5 effects.
Solids / operating basis
SRT is reported on a total MLVSS inventory and loss basis.
Carbon-removal mode requires a user-selected SRT. No universal minimum carbon-removal SRT is applied.
Advanced assumptions & solids boundariesProject editable
SCREENING / PROJECT ASSUMPTION — these starting values are not universal constants or EPA defaults. Replace them with site measurements or calibrated project values.
Ergebnisse im Überblick
Detaillierte technische Ergebnisse
Projekt / Auslegungsbasis
| Parameter | Wert | Einheit |
|---|---|---|
| Project / case | Municipal carbon removal reference | — |
| Process mode | Carbon removal | — |
| Flow | 10,000 | m³/d |
| Temperature | 20 | °C |
Zu- / Ablaufbasis
| Parameter | Wert | Einheit |
|---|---|---|
| Biological substrate basis policy | BOD5 — user-selected biological design basis | — |
| Influent BOD5 | 210 | mg/L as BOD5 (O₂) |
| Effluent target BOD5 | 10 | mg/L as BOD5 (O₂) |
| Applied BOD5 load | 2,100 | kg BOD5/d |
| Removed BOD5 load | 2,000 | kg BOD5/d |
Substrat- und Biomassebilanz
| Parameter | Wert | Einheit |
|---|---|---|
| Gross heterotroph synthesis | 1,200 | kg VSS/d |
| Heterotroph decay rate at design temperature | 0.05 | d⁻¹ |
| Heterotroph decay loss | 400 | kg VSS/d |
| Net active heterotroph production | 800 | kg VSS/d |
| Influent inert VSS | 200 | kg VSS/d |
| Endogenous residue | 0 | kg VSS/d |
| Fixed / inorganic solids | 230 | kg TSS/d |
| External chemical solids | 0 | kg TSS/d |
| Total VSS production | 1,000 | kg VSS/d |
| Total TSS production | 1,230 | kg TSS/d |
| Total MLVSS inventory | 10,000 | kg VSS |
| Total MLSS inventory | 12,300 | kg TSS |
| VSS/TSS production fraction | 0.813 | kg VSS/kg TSS |
Feststoffinventar / SRT
| Parameter | Wert | Einheit |
|---|---|---|
| Achieved MLVSS SRT | 10 | d |
| Removed-basis F/M | 0.2 | kg BOD5/(kg MLVSS·d) |
RAS / WAS
WAS ist ein externer Feststoffverlust; RAS ist interner Rücklauf.
| Parameter | Wert | Einheit |
|---|---|---|
| Required WAS flow | 141.427 | m³/d |
| WAS solids loss | 1,131.414 | kg TSS/d |
| Effluent TSS loss | 98.586 | kg TSS/d |
| Process RAS requirement | 7,504.444 | m³/d |
| RAS / influent flow ratio | 0.75 | m³/m³ |
Biologischer Sauerstoffbedarf
| Parameter | Wert | Einheit |
|---|---|---|
| Carbonaceous AOR | 1,864 | kg O₂/d |
| Nitrification AOR | 0 | kg O₂/d |
| Denitrification oxygen credit | 0 | kg O₂/d |
| Average total AOR | 1,864 | kg O₂/d |
| Peak AOR | Nicht verfügbar | kg O₂/d |
Massenbilanzschluss und Diagnostik
Erzeugte TSS = externer WAS-Verlust + Ablaufverlust an der vorgegebenen Grenze.
| Parameter | Wert | Einheit |
|---|---|---|
| Authoritative closure state | PASS | — |
| Generated TSS | 1,230 | kg TSS/d |
| WAS external loss | 1,131.414 | kg TSS/d |
| Effluent external loss | 98.586 | kg TSS/d |
| Closure residual | 0 | kg TSS/d |
Modellannahmen und Koeffizientenquellen
Screening-Werte sind Projektangaben, keine universellen Konstanten oder EPA-Standardwerte. Die vollständige Herkunft bleibt im technischen Bericht erhalten.
US EPA, Biological Concepts for Design and Operation of the Activated Sludge Process; empirical cell formula C5H7NO2 and oxygen equivalent 160/113.
| Koeffizient / Annahme | Wert | Einheit | Quellentyp |
|---|---|---|---|
| Flow/concentration mass-load divisor | 1,000 | L/m³ and mg/g | Referenzgestützt |
| Heterotroph gross yield on BOD5 removed | 0.6 | kg VSS/kg BOD5 removed | Screening-Annahme |
| Heterotroph endogenous decay at 20°C | 0.05 | d⁻¹ | Screening-Annahme |
| Heterotroph decay temperature coefficient | 1.04 | dimensionless | Screening-Annahme |
| Biomass nitrogen content | 0.08 | kg N/kg active VSS | Screening-Annahme |
| Endogenous residue fraction of decay | 0 | dimensionless | Screening-Annahme |
| Influent inert VSS load | 200 | kg VSS/d | Screening-Annahme |
| Influent fixed/inorganic TSS load | 230 | kg TSS/d | Screening-Annahme |
| Externally supplied chemical TSS | 0 | kg TSS/d | Screening-Annahme |
| WAS TSS concentration | 8,000 | mg/L as TSS | Screening-Annahme |
| RAS/underflow TSS concentration | 8,000 | mg/L as TSS | Screening-Annahme |
| Imposed effluent TSS boundary | 10 | mg/L as TSS | Screening-Annahme |
| Project RAS/plant-flow operational screen | 1.2 | m³/m³ | Screening-Annahme |
| Ultimate BOD to BOD5 ratio | 1.5 | kg BODu/kg BOD5 | Screening-Annahme |
| Biomass synthesis oxygen equivalent | 1.42 | kg O2/kg VSS | Referenzgestützt |
Technische Warnungen & Technische Grenzen und Annahmen
Keine aktiven Berechnungswarnungen.
- Effluent-TSS ist eine vorgegebene Grenze; die Nachklärung wird nicht vorhergesagt.
- AOR ist biologischer Sauerstoffbedarf; Sauerstoffübertragung und Gebläse liegen außerhalb des Umfangs.
- Die Restalkalinität wird ausgewiesen; keine Chemikaliendosierung wird bemessen.
Engineering report and exports
PDF preview, print, and download use the same generated report. Any input edit invalidates its accepted result snapshot.
Ingenieurtechnische Grundlage
Methodik
Deterministic steady-state process calculation on an explicit BOD5 or COD basis. Heterotroph synthesis and decay remain separate from inert and fixed solids.
The selected BOD5 or COD values are the biological design substrate basis. COD is used as entered without automatic fractionation into biodegradable, soluble, inert, or particulate non-biodegradable COD; provide an appropriate project/site biological COD basis or explicitly accept the un-fractionated screening assumption. For BOD5, the model does not predict downstream clarification-related particulate BOD5 effects.
Selected SRT is defined on total MLVSS inventory divided by external MLVSS loss. Carbon-removal mode requires a user-selected SRT; nitrification mode screens minimum SRT from temperature, effluent NH4-N, DO, AOB growth and decay.
F/M is applied substrate load divided by aeration-tank MLVSS inventory. Biological AOR is calculated before oxygen transfer and blower requirements.
Normen / Referenzgrundlage
Annahmen
- Heterotroph yield, decay, temperature correction, BODu/BOD5, biomass nitrogen content and solids composition are visible project or screening assumptions, not universal EPA defaults.
- The EPA-based AOB coefficient set is a reference set only; project/site calibrated overrides remain available and carry their source note.
- Secondary-effluent TSS is an imposed design boundary unless a later clarifier model supplies a prediction.
Umfang / Grenzen
- Preliminary steady-state activated-sludge process calculation; no dynamic, toxicity, alkalinity reagent-dose, denitrification, EBPR or chemical phosphorus model.
- Process RAS continuity is an algebraic solids-balance requirement. It does not predict settling flux, blanket behavior, clarifier geometry capacity or effluent TSS.
- Biological AOR is not oxygen-transfer performance, diffuser airflow or blower sizing. OxyMatrix remains the oxygen-transfer authority.
Ingenieurpfad
Konventioneller Belebtschlamm-Zweig
- Primärklärung des Abwassers
- Belebtschlamm-Auslegung
- OxyMatrixOxyMatrix ist ein unabhängiger Rechner für Sauerstoffübertragung und Gebläse. Sauerstoffbedarfsgrundlage dort eingeben und prüfen.
- Sekundäre Feststofftrennung — FluxMatrixAbsetzverhalten und Kapazität des Nachklärbeckens werden getrennt von der Prozess-RAS-Kontinuität bewertet.
Alternativer Nährstoffentfernungs-Zweig
- BNRMatrixAlternativer biologischer Prozess für Nährstoffentfernung; kein notwendiger Folgeschritt dieses Werkzeugs.