Skip to main content
Torna a Strumenti

Strumento di ingegneria · Membrane

Progettista di Sistemi NF

Modella il bilancio di massa della nanofiltrazione con monitoraggio indipendente del rigetto monovalente (sale) e divalente (durezza) per configurazioni fino a 3 stadi, oltre a un risolutore per il flusso di bypass necessario per raggiungere una durezza finale target.

Acqua ad alta purezzaFase 01 — Pretrattamento
Stato
Strumento di Ingegneria Live
Condizioni
Iniziale / invecchiato
Configurazione
Singolo stadio / multistadio
Unità
Metrico / imperiale
ATLAS WTS · Process Engineering

NF System Designer

Nanofiltration mass-balance with selective monovalent/divalent (hardness) rejection tracking, up to 3-stage arrays, membrane-aging projection, and product-water blending — including a solver for the bypass flow needed to hit a target finished hardness.

Cloud Engine
Project Information
Feed Water & Application

Pressure & Membrane Configuration

2- and 3-stage arrays feed each stage from the prior stage's concentrate, raising overall system recovery beyond what a single stage can reach — standard for hitting the 80-90% system recoveries common in NF softening.

Stage 1

ΔP guidance: ~0.2–0.3 bar (~3–4 psi) friction loss per element in series, ≈1.2–2.4 bar for a standard 6–8-element vessel — independent of how many vessels feed this stage in parallel.
Stage 2 Optional

ΔP guidance: ~0.2–0.3 bar/element in series, ≈1.2–2.4 bar for a standard 6–8-element vessel.

Re-pressurizes Stage 1's concentrate before it enters Stage 2, independent of the main feed pump — useful when this stage would otherwise run short on net driving pressure, especially at high recovery or aged-membrane conditions.

Stage 3 Optional

ΔP guidance: ~0.2–0.3 bar/element in series, ≈1.2–2.4 bar for a standard 6–8-element vessel.

Re-pressurizes Stage 2's concentrate before it enters Stage 3, independent of the main feed pump.

Membrane Aging Projection

Defaults follow the selected application type; edit for a specific project. The "Aged" condition (toggle top-right) projects permeate TDS/hardness and required feed pressure at end of the stated membrane age — both monovalent and divalent passage increase by the same compounding rate.

Product Water Blending (Bypass)

Raw/pretreated water blended directly into the final product stream — the standard NF softening lever for hitting a target finished hardness economically without over-designing rejection. Leave flow at 0 to disable.

Solve for Target Finished Hardness

Back-solves the bypass flow (at current membrane-train performance, using the on-screen Day-1/Aged condition) needed to blend the membrane permeate up to a target finished hardness. Only valid for a target strictly between membrane permeate hardness and configured bypass-stream hardness; either stream may have the higher hardness.

Overall System (Membrane Train + Blend)
Final Product Flow
—m³/h
Final Product TDS
—ppm
Final Product Hardness
—mg/L
Overall Hardness Removal
—%
Overall System Recovery
—%
of total raw intake incl. bypass
Waste (To Drain)
—m³/h
Membrane Train Performance
Train Recovery
—%
Total Permeate Flow
—m³/h
Final Concentrate Flow
—m³/h
Permeate TDS
—ppm
Permeate Hardness
—mg/L
Concentrate TDS
—ppm
Concentrate Hardness
—mg/L
Monovalent (TDS) Rejection
—%
Divalent (Hardness) Rejection
—%
Total Membrane Area
—m²
System Average Flux
—LMH
Stage-by-Stage Breakdown
StageElementsRecoveryNDPOsmotic P.FluxMono. Rej.Div. Rej.Perm. FlowPerm. TDSPerm. HardnessConc. TDSConc. Hardness
Membrane Chemistry Reference (Informational)
Technical Warnings
No warnings — all parameters within the modeled envelope.

Powered by ATLAS WTS

Questo strumento di ingegneria è attualmente disponibile solo in inglese.

01

Base ingegneristica

Metodologia

I calcoli di bilancio di massa e flusso seguono la forma standard basata sul recupero (Qp = Qf·Y), con la pressione motrice netta derivata dalla pressione di alimentazione meno le perdite lato concentrato e la pressione osmotica media logaritmica lato membrana lungo lo stadio.

Il passaggio di sale monovalente e divalente è normalizzato in modo indipendente per temperatura e flusso rispetto alla condizione di prova al banco della membrana, riflettendo il comportamento di rigetto selettivo caratteristico della nanofiltrazione, a differenza del rigetto uniforme del sale totale dell'osmosi inversa.

Norme / Base di riferimento

NF 15–25 LMHIndipendente dal fornitore

Ipotesi

  • Gli array a uno o più stadi usano le opzioni esistenti per elementi da 4, 8 e 16 pollici.
  • Le condizioni iniziali/invecchiate e la miscelazione di bypass restano parte del modello esistente.

Ambito / Limiti

  • Solo classi di chimica NF lasca/stretta neutrali; modellazione del rigetto selettivo, invecchiamento della membrana e miscelazione di bypass calibrati per addolcimento di acqua di pozzo, acqua superficiale e controllo dell'incrostazione.
02

Percorso ingegneristico

Applicazione

Scenario

Flusso di lavoro

  • Acqua ad alta purezzaPercorso ad alta purezza dal pretrattamento dell’alimentazione, attraverso RO, polishing, scambio ionico o CEDI, controllo finale e distribuzione.
    Fase 01 — PretrattamentoTorna alla fase 01