Skip to main content
돌아가기: 도구

엔지니어링 도구 · 멤브레인

NF 시스템 설계 도구

1가(염분) 및 2가(경도) 제거율을 독립적으로 추적하는 나노여과 물질수지를 모델링하며 최대 3단 배열을 지원하고, 목표 최종 경도 달성에 필요한 바이패스 혼합 유량을 역산하는 솔버를 포함합니다.

상태
실시간 엔지니어링 도구
조건
초기 / 노후
배열
단일 단계 / 다단계
단위
미터법 / 야드·파운드법
ATLAS WTS · Process Engineering

NF System Designer

Nanofiltration mass-balance with selective monovalent/divalent (hardness) rejection tracking, up to 3-stage arrays, membrane-aging projection, and product-water blending — including a solver for the bypass flow needed to hit a target finished hardness.

Cloud Engine
Project Information
Feed Water & Application

Pressure & Membrane Configuration

2- and 3-stage arrays feed each stage from the prior stage's concentrate, raising overall system recovery beyond what a single stage can reach — standard for hitting the 80-90% system recoveries common in NF softening.

Stage 1

ΔP guidance: ~0.2–0.3 bar (~3–4 psi) friction loss per element in series, ≈1.2–2.4 bar for a standard 6–8-element vessel — independent of how many vessels feed this stage in parallel.
Stage 2 Optional

ΔP guidance: ~0.2–0.3 bar/element in series, ≈1.2–2.4 bar for a standard 6–8-element vessel.

Re-pressurizes Stage 1's concentrate before it enters Stage 2, independent of the main feed pump — useful when this stage would otherwise run short on net driving pressure, especially at high recovery or aged-membrane conditions.

Stage 3 Optional

ΔP guidance: ~0.2–0.3 bar/element in series, ≈1.2–2.4 bar for a standard 6–8-element vessel.

Re-pressurizes Stage 2's concentrate before it enters Stage 3, independent of the main feed pump.

Membrane Aging Projection

Defaults follow the selected application type; edit for a specific project. The "Aged" condition (toggle top-right) projects permeate TDS/hardness and required feed pressure at end of the stated membrane age — both monovalent and divalent passage increase by the same compounding rate.

Product Water Blending (Bypass)

Raw/pretreated water blended directly into the final product stream — the standard NF softening lever for hitting a target finished hardness economically without over-designing rejection. Leave flow at 0 to disable.

Solve for Target Finished Hardness

Back-solves the bypass flow (at current membrane-train performance, using the on-screen Day-1/Aged condition) needed to blend the membrane permeate up to a target finished hardness. Only valid for a target strictly between membrane permeate hardness and configured bypass-stream hardness; either stream may have the higher hardness.

Overall System (Membrane Train + Blend)
Final Product Flow
—m³/h
Final Product TDS
—ppm
Final Product Hardness
—mg/L
Overall Hardness Removal
—%
Overall System Recovery
—%
of total raw intake incl. bypass
Waste (To Drain)
—m³/h
Membrane Train Performance
Train Recovery
—%
Total Permeate Flow
—m³/h
Final Concentrate Flow
—m³/h
Permeate TDS
—ppm
Permeate Hardness
—mg/L
Concentrate TDS
—ppm
Concentrate Hardness
—mg/L
Monovalent (TDS) Rejection
—%
Divalent (Hardness) Rejection
—%
Total Membrane Area
—m²
System Average Flux
—LMH
Stage-by-Stage Breakdown
StageElementsRecoveryNDPOsmotic P.FluxMono. Rej.Div. Rej.Perm. FlowPerm. TDSPerm. HardnessConc. TDSConc. Hardness
Membrane Chemistry Reference (Informational)
Technical Warnings
No warnings — all parameters within the modeled envelope.

Powered by ATLAS WTS

이 엔지니어링 도구는 현재 영어로만 제공됩니다.

01

엔지니어링 근거

방법론

물질수지 및 플럭스 계산은 회수율 기반 표준 형식(Qp = Qf·Y)을 따르며, 순구동압력은 공급 압력에서 농축수 측 손실과 해당 단의 막벽 측 로그평균 삼투압을 빼진 값으로 산출합니다.

1가 및 2가 염 투과율은 각각 독립적으로 멤브레인의 벤치 테스트 기준 조건 대비 온도 및 플럭스로 정규화되며, 이는 역삼투의 균일한 총 염 제거와 달리 나노여과 고유의 선택적 제거 특성을 반영합니다.

표준 / 참조 근거

NF 15–25 LMH공급업체 중립

가정

  • 단일 또는 다단 배열은 기존 4, 8, 16인치 요소 크기 옵션을 사용합니다.
  • 초기/노후 조건과 바이패스 혼합은 기존 계산기 모델에 포함됩니다.

범위 / 제한사항

  • 제조사 중립적인 루즈/타이트 NF 화학 등급만 사용. 선택적 제거 모델링, 멤브레인 노화, 바이패스 혼합은 지하수·지표수·스케일 제어 연수화 공정에 맞춰 보정.
02

엔지니어링 경로

적용 분야

시나리오

워크플로

  • 고순도수원수 전처리, RO, 폴리싱, 이온교환 또는 CEDI, 최종 품질관리와 분배 시스템으로 이어지는 고순도수 경로입니다.
    단계 01 — 전처리단계로 돌아가기 01