Estabilidad del agua y química de carbonatos

Calcule la especiación exclusiva de carbonatos y presente de forma transparente valores de cribado de pHs, LSI y RSI.

Purificación municipal de agua potableEtapa 06 — Distribution & Final Quality
Estado
Disponible
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision ad185526

69 focused fixtures: LSI/pHs/RSI reference case, carbonate alpha fractions and DIC, active scenario inputs, symmetric diagnostics, 25 deg C speciation basis, structured comparison, exports, and stale-result behavior. Tests are deterministic and run without network access.

Esta herramienta de ingeniería está disponible actualmente solo en inglés.

01

Base de ingeniería

Metodología

Calcula pHs, LSI y RSI empíricos con las propiedades ingresadas del agua y aproxima la especiación de carbonatos con constantes de referencia fijas cercanas a 25 °C. Son índices de cribado, no un equilibrio geoquímico completo, una tasa de corrosión ni una recomendación automática de dosis química.

The empirical saturation-pH calculation uses entered water temperature: A = (log10(TDS) - 1)/10, B = -13.12 log10(T + 273) + 34.55, C = log10(calcium hardness) - 0.4, D = log10(alkalinity), and pHs = (9.3 + A + B) - (C + D).

LSI = measured pH - pHs. RSI = 2 pHs - measured pH.

The carbonate-only V1 approximation uses fixed reference constants at approximately 25 deg C: pKa1 = 6.35, pKa2 = 10.33, and Kw = 1e-14. Alpha fractions are calculated from hydrogen concentration and these constants.

Approximate DIC = (alkalinity equivalents - hydroxide + hydrogen)/(alpha1 + 2 alpha2), with alkalinity converted from mg/L as CaCO3 to equivalents per litre.

For current water and an enabled adjusted scenario, LSI uses the respective entered water temperature. Carbonate-only speciation continues to use fixed 25 deg C constants.

Scenario values are entered directly. The tool does not calculate a chemical dose or predict the effect of a treatment process.

Alcance / Limitaciones

  • La especiación usa constantes de referencia fijas a 25 °C, mientras que el LSI empírico usa la temperatura introducida. Los resultados son índices de cribado, no garantías de corrosión o incrustación.
  • LSI and RSI are empirical numerical screening indices; this tool does not assign categorical water-quality status.
  • Carbonate speciation is a carbonate-only approximation. It omits phosphate, silicate, organic alkalinity, and full geochemical equilibrium.
  • No corrosion rate, lead or copper compliance, CCPP, chemical-dose solver, or automatic treatment recommendation is provided.
  • CCPP is deferred.
02

Ruta de ingeniería

Contexto aguas arriba

Decisión de esta herramienta

  • Estabilidad del agua y química de carbonatos Calcule la especiación exclusiva de carbonatos y presente de forma transparente valores de cribado de pHs, LSI y RSI.

Siguiente paso de ingeniería

  • Revisión de distribución y calidad final Lleve la base de agua terminada al monitoreo de la empresa de agua, la distribución y la revisión operativa del proyecto.