Outil d’ingénierie · Traitement de l’eau

Stabilité de l’eau et chimie des carbonates

Calculez la spéciation du système carbonaté et présentez clairement les valeurs de dépistage pHs, LSI et RSI.

Purification municipale de l’eau potableÉtape 06 — Distribution & Final Quality
État
Disponible
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision ad185526

69 focused fixtures: LSI/pHs/RSI reference case, carbonate alpha fractions and DIC, active scenario inputs, symmetric diagnostics, 25 deg C speciation basis, structured comparison, exports, and stale-result behavior. Tests are deterministic and run without network access.

Cet outil d’ingénierie est actuellement disponible uniquement en anglais.

01

Base d’ingénierie

Méthodologie

Calcule pHs, LSI et RSI empiriques à partir des propriétés saisies et approche la spéciation carbonatée avec des constantes de référence fixes proches de 25 °C. Ce sont des indices de criblage, pas un équilibre géochimique complet, une vitesse de corrosion ou une recommandation automatique de dosage.

The empirical saturation-pH calculation uses entered water temperature: A = (log10(TDS) - 1)/10, B = -13.12 log10(T + 273) + 34.55, C = log10(calcium hardness) - 0.4, D = log10(alkalinity), and pHs = (9.3 + A + B) - (C + D).

LSI = measured pH - pHs. RSI = 2 pHs - measured pH.

The carbonate-only V1 approximation uses fixed reference constants at approximately 25 deg C: pKa1 = 6.35, pKa2 = 10.33, and Kw = 1e-14. Alpha fractions are calculated from hydrogen concentration and these constants.

Approximate DIC = (alkalinity equivalents - hydroxide + hydrogen)/(alpha1 + 2 alpha2), with alkalinity converted from mg/L as CaCO3 to equivalents per litre.

For current water and an enabled adjusted scenario, LSI uses the respective entered water temperature. Carbonate-only speciation continues to use fixed 25 deg C constants.

Scenario values are entered directly. The tool does not calculate a chemical dose or predict the effect of a treatment process.

Périmètre / Limites

  • La spéciation utilise des constantes de référence fixes à 25 °C, tandis que le LSI empirique utilise la température saisie. Les sorties sont des indices de dépistage, et non des garanties contre la corrosion ou l’entartrage.
  • LSI and RSI are empirical numerical screening indices; this tool does not assign categorical water-quality status.
  • Carbonate speciation is a carbonate-only approximation. It omits phosphate, silicate, organic alkalinity, and full geochemical equilibrium.
  • No corrosion rate, lead or copper compliance, CCPP, chemical-dose solver, or automatic treatment recommendation is provided.
  • CCPP is deferred.