Skip to main content
Torna a Strumenti

Strumento di ingegneria · Trattamento dell’acqua

Stabilità dell’acqua e chimica dei carbonati

Calcola la speciazione del sistema carbonatico e presenta in modo trasparente i valori di screening pHs, LSI e RSI.

Purificazione municipale dell’acqua potabileFase 06 — Distribution & Final Quality
Stato
Disponibile
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision ad185526

69 focused fixtures: LSI/pHs/RSI reference case, carbonate alpha fractions and DIC, active scenario inputs, symmetric diagnostics, 25 deg C speciation basis, structured comparison, exports, and stale-result behavior. Tests are deterministic and run without network access.

Questo strumento di ingegneria è attualmente disponibile solo in inglese.

01

Base ingegneristica

Metodologia

Calcola pHs, LSI e RSI empirici dalle proprietà dell’acqua inserite e approssima la speciazione carbonatica con costanti di riferimento fisse vicine a 25 °C. Sono indici di screening, non un equilibrio geochimico completo, una velocità di corrosione o una raccomandazione automatica di dosaggio.

The empirical saturation-pH calculation uses entered water temperature: A = (log10(TDS) - 1)/10, B = -13.12 log10(T + 273) + 34.55, C = log10(calcium hardness) - 0.4, D = log10(alkalinity), and pHs = (9.3 + A + B) - (C + D).

LSI = measured pH - pHs. RSI = 2 pHs - measured pH.

The carbonate-only V1 approximation uses fixed reference constants at approximately 25 deg C: pKa1 = 6.35, pKa2 = 10.33, and Kw = 1e-14. Alpha fractions are calculated from hydrogen concentration and these constants.

Approximate DIC = (alkalinity equivalents - hydroxide + hydrogen)/(alpha1 + 2 alpha2), with alkalinity converted from mg/L as CaCO3 to equivalents per litre.

For current water and an enabled adjusted scenario, LSI uses the respective entered water temperature. Carbonate-only speciation continues to use fixed 25 deg C constants.

Scenario values are entered directly. The tool does not calculate a chemical dose or predict the effect of a treatment process.

Ambito / Limiti

  • La speciazione usa costanti di riferimento fisse a 25 °C, mentre l’LSI empirico usa la temperatura inserita. I risultati sono indici di screening, non garanzie di corrosione o incrostazione.
  • LSI and RSI are empirical numerical screening indices; this tool does not assign categorical water-quality status.
  • Carbonate speciation is a carbonate-only approximation. It omits phosphate, silicate, organic alkalinity, and full geochemical equilibrium.
  • No corrosion rate, lead or copper compliance, CCPP, chemical-dose solver, or automatic treatment recommendation is provided.
  • CCPP is deferred.
02

Percorso ingegneristico

Contesto a monte

Decisione di questo strumento

  • Stabilità dell’acqua e chimica dei carbonati Calcola la speciazione del sistema carbonatico e presenta in modo trasparente i valori di screening pHs, LSI e RSI.

Passaggio ingegneristico a valle

  • Verifica di distribuzione e qualità finale Trasferisce la base dell’acqua trattata al monitoraggio del gestore, alla distribuzione e alla revisione operativa del progetto.