Skip to main content
Back to Tools

Engineering Tool · Water & Wastewater Clarification

Clarifier Designer

Screen clarifier geometry, surface overflow and weir loading, detention, and one-basin-out operation.

Status
Available
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision 256b18f5

85 focused fixtures: focused engineering fixtures for geometry, operating cases, criteria, optional inputs, independent hand-calculated cases, finite-result boundaries, result presentation, and active-input export behavior. Tests are deterministic and run without network access.

01

Engineering Basis

Methodology

Uses the selected basin geometry and active basin count to calculate plan area, surface overflow, detention, weir loading, optional solids loading, and one-unit-out cases. Criteria and geometry are user supplied; this screen does not predict settling/removal or determine code or regulatory compliance.

Basin plan area uses only the selected geometry: length × width, pi × diameter squared / 4, or the entered area.

Surface overflow rate = design flow / active plan area. Volume = active area × side-water depth; detention time = volume / design flow.

Weir loading = design flow / active weir length. One-unit-out calculations use N - 1 identical basins and their remaining weir length.

Solids loading = the entered plant solids mass flow / active plan area. The same plant solids mass flow is distributed across the remaining active area for the one-unit-out case.

Scope / Limitations

  • Compare rectangular, circular, or directly entered basin area against flow, depth, weir, and optional user criteria, including explicit N−1 warnings.
  • This screening calculation does not perform CFD, predict settling or particle removal, or guarantee treatment performance.
  • It does not provide structural, mechanical, scraper, or detailed clarifier design.
  • Criterion comparisons use user-entered values and do not determine code or regulatory compliance.
02

Engineering Path

Drinking Water Path