Skip to main content
Back to Tools

Engineering Tool · Wastewater Treatment

OxyMatrix Aeration & Oxygen Transfer Engineering

Evaluate biological oxygen demand, oxygen-transfer performance, diffuser air requirements and blower sizing for preliminary wastewater aeration design.

Status
Available
Units
Metric / Imperial display
Calculation serviceUnavailable
Engineering resultNot available

Automatic calculation · preliminary design

1. Biological Process & Oxygen Demands

Carbonaceous demand, nitrification stoichiometry & denitrification credit

Stage 1 /
Qm³/d
°C
mg/L
Target
mg/L
Biological Screening AssumptionsUse project/site-specific values where available.
g VSS/g BOD₅
Per gram of removed
Factor
mg/L
Target
mg/L
mg/L
By denitrification · oxygen credit
mg/L
PF
Peak oxygen-demand multiplier
mg/L

2. Submerged Physics & Reference Transfer

Diffuser submergence, pressure screening, and standard oxygen requirement

Stage 2 /
Hm
Hᵈm
fₑ
Effective depth = fraction × basin liquid depth
zm
Above sea level
Depth Slope
%/m
Per metre of diffuser submergence
α
Process-water correction
β
Dissolved-oxygen saturation correction
F
Diffuser fouling allowance
θ
Temperature correction for transfer kinetics
ΔPᵈkPa
ΔPₚkPa

3. Blower Thermodynamics & Sizing

Compression technology, isentropic efficiency, and wire power

Stage 3 / Power

Selecting a technology loads its reference screening efficiency into the editable current design fields.

°C
°C
%
Technology Reference82%
Current Design75%
Modified from reference
%
Technology reference: 82%
%
Editable design input
%
Editable design input
CAD/kWh
h/yr
Calculation service unavailableNo result is available because the calculation service could not be reached. Your inputs remain available.

Submerged Aeration Tank — Design Schematic

Submergence, pressure and oxygen-transfer context

Unavailable
No diagram resultThe calculation service is unavailable; the diagram will appear after a successful response.
Reference-based preliminary design. Review engineering assumptions and limitations in Derivations.
01

Engineering Basis

Methodology

Use the oxygen-demand value and assumptions that you enter in OxyMatrix. Values from other tools are optional manual references; results are not imported or shared. OxyMatrix independently screens oxygen transfer, air demand, diffuser layout, blower performance, and energy use.

Assumptions

  • Review the alpha and beta factors, standard oxygen transfer efficiency (SOTE), dissolved oxygen (DO), diffuser submergence and site elevation for the stated process conditions.

Scope / Limitations

  • Reference-based preliminary screening and design. Detailed design requires project-specific engineering review and supplier performance data; results do not constitute certification, a vendor guarantee or regulatory approval.
02

Engineering Path

Activated Sludge Designer and BNRMatrix are optional references only. If you use their AOR, review it and its assumptions, then enter both manually in OxyMatrix. No tool-to-tool API connection, automatic transfer, shared calculation state, or one-click import/export is provided.

Application

Scenario

Workflow

  • WastewaterEight decision stages from influent acceptance through preliminary and primary treatment, alternative biological paths, secondary solids separation, optional polishing, disinfection, and effluent/reuse/discharge review.
    Stage 04 — Biological Treatment & Nutrient RemovalReturn to Stage 04