Skip to main content
Volver a Herramientas

Herramienta de ingeniería · Tanques y Estanques

Diseño de flotación por aire disuelto (DAF)

Evalúe preliminarmente la hidráulica de recirculación de la flotación por aire disuelto, las cargas, la masa de aire liberado, la relación aire/sólidos y el tiempo de contacto.

Purificación municipal de agua potableEtapa 03 — Clarification & Filtration
Estado
Disponible
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision 22463161

59 focused fixtures: independent recycle, hydraulic loading, air-mass, air-to-solids, and contact-time cases; numerical boundaries, criterion comparison, and input rejection. Tests are deterministic and run without network access.

Esta herramienta de ingeniería está disponible actualmente solo en inglés.

01

Base de ingeniería

Metodología

Separa el caudal bruto del reciclado para calcular cargas hidráulicas y deriva la masa de aire liberado y la relación aire/sólidos a partir del reciclado, la concentración de aire y los sólidos ingresados. El tiempo de contacto es un cribado nominal de volumen/caudal, no una distribución de tiempos de residencia ni una garantía de remoción.

Recycle flow = recycle fraction × raw flow. Total hydraulic flow includes raw plus recycle.

Raw-flow surface loading uses raw flow; total hydraulic loading uses raw flow plus recycle flow.

Released-air mass = recycle flow × user-entered effective released-air concentration, with mg/L converted to kg/m³. Air-to-solids ratio = released-air mass / entered solids mass basis.

Contact-time screening uses raw flow plus recycle flow through the entered contact/separation volume. Calculated contact time = volume / total hydraulic flow.

Alcance / Limitaciones

  • Calcule el caudal de recirculación, la carga hidráulica del agua bruta y total, el aire liberado y la relación A/S a partir de los datos declarados; puede incluir criterios opcionales de sólidos y volumen de contacto.
  • Calculated hydraulic contact time is a nominal volume/flow screening value and does not represent actual residence-time distribution.
  • Effective released-air concentration is user-entered. This version does not derive saturator performance from pressure, temperature, or Henry law.
  • The air-to-solids ratio is a design-basis ratio and is not an adequacy, optimization, or solids-removal guarantee.
  • This screening tool does not predict bubble size, perform CFD, select recycle pumps, or guarantee solids-removal performance.
02

Ruta de ingeniería

Contexto aguas arriba

Decisión de esta herramienta

  • Diseño de flotación por aire disuelto (DAF) Evalúe preliminarmente la hidráulica de recirculación de la flotación por aire disuelto, las cargas, la masa de aire liberado, la relación aire/sólidos y el tiempo de contacto.

Siguiente paso de ingeniería