Skip to main content
Torna a Strumenti

Strumento di ingegneria · Serbatoi e Vasche

Progettazione della flottazione ad aria disciolta (DAF)

Valuta preliminarmente l’idraulica del ricircolo della flottazione ad aria disciolta, i carichi, la massa d’aria rilasciata, il rapporto aria/solidi e il tempo di contatto.

Purificazione municipale dell’acqua potabileFase 03 — Clarification & Filtration
Stato
Disponibile
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision 22463161

59 focused fixtures: independent recycle, hydraulic loading, air-mass, air-to-solids, and contact-time cases; numerical boundaries, criterion comparison, and input rejection. Tests are deterministic and run without network access.

Questo strumento di ingegneria è attualmente disponibile solo in inglese.

01

Base ingegneristica

Metodologia

Separa la portata grezza da quella di ricircolo per i carichi idraulici, quindi ricava massa d’aria rilasciata e rapporto aria/solidi dai dati inseriti. Il tempo di contatto è una stima nominale volume/portata, non una distribuzione dei tempi di residenza né una garanzia di rimozione.

Recycle flow = recycle fraction × raw flow. Total hydraulic flow includes raw plus recycle.

Raw-flow surface loading uses raw flow; total hydraulic loading uses raw flow plus recycle flow.

Released-air mass = recycle flow × user-entered effective released-air concentration, with mg/L converted to kg/m³. Air-to-solids ratio = released-air mass / entered solids mass basis.

Contact-time screening uses raw flow plus recycle flow through the entered contact/separation volume. Calculated contact time = volume / total hydraulic flow.

Ambito / Limiti

  • Calcola portata di ricircolo, carico idraulico dell’acqua grezza e totale, aria rilasciata e rapporto A/S dai dati dichiarati; sono disponibili criteri facoltativi per solidi e volume di contatto.
  • Calculated hydraulic contact time is a nominal volume/flow screening value and does not represent actual residence-time distribution.
  • Effective released-air concentration is user-entered. This version does not derive saturator performance from pressure, temperature, or Henry law.
  • The air-to-solids ratio is a design-basis ratio and is not an adequacy, optimization, or solids-removal guarantee.
  • This screening tool does not predict bubble size, perform CFD, select recycle pumps, or guarantee solids-removal performance.
02

Percorso ingegneristico

Contesto a monte

Decisione di questo strumento

  • Progettazione della flottazione ad aria disciolta (DAF) Valuta preliminarmente l’idraulica del ricircolo della flottazione ad aria disciolta, i carichi, la massa d’aria rilasciata, il rapporto aria/solidi e il tempo di contatto.

Passaggio ingegneristico a valle