Skip to main content
Volver a Herramientas

Herramienta de ingeniería · Tratamiento de agua

Diseño de filtros de medios granulares

Revise la carga en operación normal y con un filtro fuera de servicio, la pérdida de carga en medios multicapa y el agua de retrolavado necesaria.

Purificación municipal de agua potableEtapa 03 — Clarification & Filtration
Estado
Disponible
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Enter each layer's volume-equivalent spherical particle diameter and separate sphericity. If a supplier gives an already shape-corrected surface-volume diameter, divide it by sphericity before entry.

Sand
Sand
Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision 4f9f386b

66 focused fixtures: independent filter-bank, backwash, and multilayer Ergun cases; selected headloss basis, optional expansion, finite-result boundaries, validation, and structured reporting. Tests are deterministic and run without network access.

Esta herramienta de ingeniería está disponible actualmente solo en inglés.

01

Base de ingeniería

Metodología

Calcula carga normal y con un filtro fuera de servicio, caudal/volumen de retrolavado y pérdida de carga Ergun en lecho limpio y multicapa usando las propiedades ingresadas del medio y del agua. Introduzca el diámetro esférico equivalente por volumen y aplique la esfericidad por separado; Ergun es un cribado de lecho limpio.

Normal rate = plant design flow / total active filter area. One-filter-out rate uses (N−1) equal filter areas. Rates are reported in m/d and m/h.

Backwash flow = backwash rate × area per filter. Wash volume = flow × duration. Daily volume includes entered washes per filter per day.

Backwash-water fraction = gross daily backwash-water volume / entered plant design flow; it does not represent net recovery.

Clean-bed headloss uses the Ergun equation for each entered layer and sums the layer losses. Enter the volume-equivalent spherical particle diameter; sphericity is applied separately. Velocity converts m/h to m/s; pressure drop converts to head using entered density and standard gravitational acceleration.

A declared bed expansion is applied to layer depth for a geometric screen only. Leaving it blank omits that screen.

Alcance / Limitaciones

  • Compare el caso normal, N−1 o definido por el usuario usando las propiedades declaradas del medio, el caudal y la duración del retrolavado, y la expansión opcional del lecho.
  • Does not recommend media chemistry, predict terminal run time from turbidity, predict pathogen removal, or claim regulatory filter credit.
  • Ergun output is a clean-bed screening estimate. Volume-equivalent spherical diameter, porosity, sphericity, and water properties must be supplied explicitly; do not enter an already shape-corrected surface-volume diameter without converting it first.
  • Bed expansion is not predicted from wash hydraulics.
02

Ruta de ingeniería

Contexto aguas arriba

  • Base seleccionada de control previo de sólidos Confirme las condiciones del agua de alimentación y el control de sólidos antes de aplicar el cribado del medio o barrera avanzada.

Decisión de esta herramienta

  • Diseño de filtros de medios granulares Revise la carga en operación normal y con un filtro fuera de servicio, la pérdida de carga en medios multicapa y el agua de retrolavado necesaria.

Siguiente paso de ingeniería