Skip to main content
Voltar para Ferramentas

Ferramenta de engenharia · Tanques e Bacias

Projeto de flotação por ar dissolvido (DAF)

Avalie preliminarmente a hidráulica de recirculação da flotação por ar dissolvido, as cargas, a massa de ar liberado, a relação ar/sólidos e o tempo de contato.

Purificação municipal de água potávelEtapa 03 — Clarification & Filtration
Status
Disponível
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision 22463161

59 focused fixtures: independent recycle, hydraulic loading, air-mass, air-to-solids, and contact-time cases; numerical boundaries, criterion comparison, and input rejection. Tests are deterministic and run without network access.

Esta ferramenta de engenharia está disponível atualmente apenas em inglês.

01

Base de engenharia

Metodologia

Separa a vazão bruta da vazão de reciclo para calcular cargas hidráulicas e deriva massa de ar liberado e relação ar/sólidos a partir dos dados informados. O tempo de contato é uma triagem nominal volume/vazão, não uma distribuição do tempo de residência nem garantia de remoção.

Recycle flow = recycle fraction × raw flow. Total hydraulic flow includes raw plus recycle.

Raw-flow surface loading uses raw flow; total hydraulic loading uses raw flow plus recycle flow.

Released-air mass = recycle flow × user-entered effective released-air concentration, with mg/L converted to kg/m³. Air-to-solids ratio = released-air mass / entered solids mass basis.

Contact-time screening uses raw flow plus recycle flow through the entered contact/separation volume. Calculated contact time = volume / total hydraulic flow.

Escopo / Limitações

  • Calcule vazão de recirculação, carga hidráulica da água bruta e total, ar liberado e relação A/S a partir dos dados declarados, com critérios opcionais de sólidos e volume de contato.
  • Calculated hydraulic contact time is a nominal volume/flow screening value and does not represent actual residence-time distribution.
  • Effective released-air concentration is user-entered. This version does not derive saturator performance from pressure, temperature, or Henry law.
  • The air-to-solids ratio is a design-basis ratio and is not an adequacy, optimization, or solids-removal guarantee.
  • This screening tool does not predict bubble size, perform CFD, select recycle pumps, or guarantee solids-removal performance.
02

Caminho de engenharia

Contexto a montante

Decisão desta ferramenta

  • Projeto de flotação por ar dissolvido (DAF) Avalie preliminarmente a hidráulica de recirculação da flotação por ar dissolvido, as cargas, a massa de ar liberado, a relação ar/sólidos e o tempo de contato.

Próxima etapa de engenharia