Progettazione dei filtri a letto granulare

Esamina il carico in esercizio normale e con un filtro fuori servizio, le perdite di carico dei mezzi multistrato e il fabbisogno d’acqua di controlavaggio.

Purificazione municipale dell’acqua potabileFase 03 — Clarification & Filtration
Stato
Disponibile
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Enter each layer's volume-equivalent spherical particle diameter and separate sphericity. If a supplier gives an already shape-corrected surface-volume diameter, divide it by sphericity before entry.

Sand
Sand
Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision 4f9f386b

66 focused fixtures: independent filter-bank, backwash, and multilayer Ergun cases; selected headloss basis, optional expansion, finite-result boundaries, validation, and structured reporting. Tests are deterministic and run without network access.

Questo strumento di ingegneria è attualmente disponibile solo in inglese.

01

Base ingegneristica

Metodologia

Calcola carichi normali e con un filtro fuori servizio, portata/volume di controlavaggio e perdita di carico Ergun a letto pulito multistrato usando le proprietà inserite. Inserire il diametro sferico equivalente in volume e applicare separatamente la sfericità; Ergun è una stima a letto pulito.

Normal rate = plant design flow / total active filter area. One-filter-out rate uses (N−1) equal filter areas. Rates are reported in m/d and m/h.

Backwash flow = backwash rate × area per filter. Wash volume = flow × duration. Daily volume includes entered washes per filter per day.

Backwash-water fraction = gross daily backwash-water volume / entered plant design flow; it does not represent net recovery.

Clean-bed headloss uses the Ergun equation for each entered layer and sums the layer losses. Enter the volume-equivalent spherical particle diameter; sphericity is applied separately. Velocity converts m/h to m/s; pressure drop converts to head using entered density and standard gravitational acceleration.

A declared bed expansion is applied to layer depth for a geometric screen only. Leaving it blank omits that screen.

Ambito / Limiti

  • Confronta il caso normale, N−1 o personalizzato in base alle proprietà dichiarate del mezzo, alla portata e durata del controlavaggio e all’eventuale espansione del letto.
  • Does not recommend media chemistry, predict terminal run time from turbidity, predict pathogen removal, or claim regulatory filter credit.
  • Ergun output is a clean-bed screening estimate. Volume-equivalent spherical diameter, porosity, sphericity, and water properties must be supplied explicitly; do not enter an already shape-corrected surface-volume diameter without converting it first.
  • Bed expansion is not predicted from wash hydraulics.
02

Percorso ingegneristico

Contesto a monte

  • Base selezionata di controllo dei solidi a monte Conferma le ipotesi sull’acqua di alimentazione e sul controllo dei solidi prima dello screening del mezzo o della barriera avanzata.

Decisione di questo strumento

  • Progettazione dei filtri a letto granulare Esamina il carico in esercizio normale e con un filtro fuori servizio, le perdite di carico dei mezzi multistrato e il fabbisogno d’acqua di controlavaggio.