Metodologia
Calcula carga normal e com um filtro indisponível, vazão/volume de retrolavagem e perda de carga Ergun em leito limpo multicamada com as propriedades informadas. Informe o diâmetro esférico equivalente em volume e aplique a esfericidade separadamente; Ergun é uma triagem de leito limpo.
Normal rate = plant design flow / total active filter area. One-filter-out rate uses (N−1) equal filter areas. Rates are reported in m/d and m/h.
Backwash flow = backwash rate × area per filter. Wash volume = flow × duration. Daily volume includes entered washes per filter per day.
Backwash-water fraction = gross daily backwash-water volume / entered plant design flow; it does not represent net recovery.
Clean-bed headloss uses the Ergun equation for each entered layer and sums the layer losses. Enter the volume-equivalent spherical particle diameter; sphericity is applied separately. Velocity converts m/h to m/s; pressure drop converts to head using entered density and standard gravitational acceleration.
A declared bed expansion is applied to layer depth for a geometric screen only. Leaving it blank omits that screen.