Ferramenta de engenharia · Tratamento de água

Projeto de filtros de meios granulares

Revise a carga em operação normal e com um filtro indisponível, a perda de carga dos meios multicamadas e a demanda de água de retrolavagem.

Purificação municipal de água potávelEtapa 03 — Clarificação e filtração
Status
Disponível
PROJECT · OPTIONAL

Project metadata

01 · USER INPUT

Design basis and inputs

Media layers

Enter volume-equivalent spherical particle diameter and separate sphericity. If a supplier gives an already shape-corrected surface-volume diameter, divide it by sphericity before entry. D10 is not inferred.

Media layer 1
Sand
Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to display a current result.

03 · REPORTING

Exports

Esta ferramenta de engenharia está disponível atualmente apenas em inglês.

01

Base de engenharia

Metodologia

Calcula carga normal e com um filtro indisponível, vazão/volume de retrolavagem e perda de carga Ergun em leito limpo multicamada com as propriedades informadas. Informe o diâmetro esférico equivalente em volume e aplique a esfericidade separadamente; Ergun é uma triagem de leito limpo.

Normal rate = plant design flow / total active filter area. One-filter-out rate uses (N−1) equal filter areas. Rates are reported in m/d and m/h.

Backwash flow = backwash rate × area per filter. Wash volume = flow × duration. Daily volume includes entered washes per filter per day.

Backwash-water fraction = gross daily backwash-water volume / entered plant design flow; it does not represent net recovery.

Clean-bed headloss uses the Ergun equation for each entered layer and sums the layer losses. Enter the volume-equivalent spherical particle diameter; sphericity is applied separately. Velocity converts m/h to m/s; pressure drop converts to head using entered density and standard gravitational acceleration.

A declared bed expansion is applied to layer depth for a geometric screen only. Leaving it blank omits that screen.

Escopo / Limitações

  • Compare o caso normal, N−1 ou personalizado com base nas propriedades declaradas do meio, na vazão e duração da retrolavagem e na expansão opcional do leito.
  • Does not recommend media chemistry, predict terminal run time from turbidity, predict pathogen removal, or claim regulatory filter credit.
  • Ergun output is a clean-bed screening estimate. Volume-equivalent spherical diameter, porosity, sphericity, and water properties must be supplied explicitly; do not enter an already shape-corrected surface-volume diameter without converting it first.
  • Bed expansion is not predicted from wash hydraulics.