Skip to main content
돌아가기: 도구

엔지니어링 도구 · 수처리

입상 여재 여과기 설계

정상 및 여과지 1개 정지 조건의 부하, 다층 여재 수두손실과 역세척수 요구량을 검토합니다.

상태
사용 가능
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Enter each layer's volume-equivalent spherical particle diameter and separate sphericity. If a supplier gives an already shape-corrected surface-volume diameter, divide it by sphericity before entry.

Sand
Sand
Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision 4f9f386b

66 focused fixtures: independent filter-bank, backwash, and multilayer Ergun cases; selected headloss basis, optional expansion, finite-result boundaries, validation, and structured reporting. Tests are deterministic and run without network access.

이 엔지니어링 도구는 현재 영어로만 제공됩니다.

01

엔지니어링 근거

방법론

입력된 여재와 물 특성으로 정상 및 여과지 1개 정지 부하, 역세 유량/수량, 다층 청정 여재층의 Ergun 수두손실을 계산합니다. 입자 지름은 체적 등가 구형 지름을 입력하고 구형도는 별도로 적용합니다. Ergun 결과는 청정층 선별값입니다.

Normal rate = plant design flow / total active filter area. One-filter-out rate uses (N−1) equal filter areas. Rates are reported in m/d and m/h.

Backwash flow = backwash rate × area per filter. Wash volume = flow × duration. Daily volume includes entered washes per filter per day.

Backwash-water fraction = gross daily backwash-water volume / entered plant design flow; it does not represent net recovery.

Clean-bed headloss uses the Ergun equation for each entered layer and sums the layer losses. Enter the volume-equivalent spherical particle diameter; sphericity is applied separately. Velocity converts m/h to m/s; pressure drop converts to head using entered density and standard gravitational acceleration.

A declared bed expansion is applied to layer depth for a geometric screen only. Leaving it blank omits that screen.

범위 / 제한사항

  • 선언된 여재 특성, 역세척 유량과 지속시간, 선택적 층 팽창률로 정상, N−1 또는 사용자 정의 수두손실 조건을 비교합니다.
  • Does not recommend media chemistry, predict terminal run time from turbidity, predict pathogen removal, or claim regulatory filter credit.
  • Ergun output is a clean-bed screening estimate. Volume-equivalent spherical diameter, porosity, sphericity, and water properties must be supplied explicitly; do not enter an already shape-corrected surface-volume diameter without converting it first.
  • Bed expansion is not predicted from wash hydraulics.
02

엔지니어링 경로

상류 맥락

  • 선택된 상류 고형물 제어 기준 여재 또는 고도 처리 장벽을 검토하기 전에 유입수와 고형물 제어 가정을 확인합니다.

현재 도구의 설계 결정

  • 입상 여재 여과기 설계 정상 및 여과지 1개 정지 조건의 부하, 다층 여재 수두손실과 역세척수 요구량을 검토합니다.

하류 엔지니어링 단계