Progettazione del serbatoio di acqua trattata e ricambio dell’accumulo

Calcola il ricambio dell’accumulo e la traiettoria dell’inventario del serbatoio di acqua trattata a intervalli.

Purificazione municipale dell’acqua potabileFase 06 — Distribution & Final Quality
Stato
Disponibile
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Storage intervals

Intervals continue from the previous ending inventory.

Hour 1
Hour 1
Hour 2
Hour 2
Hour 3
Hour 3
Hour 4
Hour 4
Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision f3f675ac

63 focused fixtures: turnover fixture, interval row normalization, optional bounds, initial inventory feasibility, trajectory limits, structured results, exports, and stale-result behavior. Tests are deterministic and run without network access.

Questo strumento di ingegneria è attualmente disponibile solo in inglese.

01

Base ingegneristica

Metodologia

Calcola volume utile, ricambio nominale e continuità dell’inventario per intervallo da ingressi, uscite e durate dichiarati. Il ricambio nominale non è età reale dell’acqua, RTD, tempo di contatto con tracciante T10 o CT di disinfezione; lo strumento non calcola T10.

Usable storage = gross storage × user-entered usable fraction. Operational storage is separately entered as a declared operating-storage basis and remains a subset of usable storage.

Nominal turnover time = usable storage / average throughput; nominal turnovers/day = average throughput / usable storage.

Interval continuity uses Snext = Scurrent + (Qin − Qout) × duration. When physical limits are enabled, overflow is recorded above the maximum and supply shortfall below the minimum; the modeled endpoint is limited to the applicable bound.

Working storage swing = maximum modeled inventory − minimum modeled inventory, including initial inventory and all modeled interval endpoints.

Ambito / Limiti

  • Esamina volume utilizzabile, ricambi, estremi della traiettoria e oscillazione operativa. La modalità senza limiti conserva e segnala trabocchi o carenze inseriti; la modalità con limiti li traccia esplicitamente.
  • Nominal turnover is not actual water age, residence-time distribution, T10 tracer contact time, disinfection contact time (CT), or a mixing-performance measure; this tool does not calculate T10.
  • The interval calculation is a storage continuity screen. It does not simulate hydraulics, mixing, or water quality.