Skip to main content
Voltar para Ferramentas

Ferramenta de engenharia · Projeto de Processos de Tratamento

FluxMatrix Clarificação e Separação de Sólidos

Faça o screening da sedimentação secundária, do fluxo de sólidos e das faixas operacionais de RAS a partir da geometria do tanque e das cargas.

Status
Disponível
Fase
Triagem de clarificador em regime estacionário
Unidades
Métrico / imperial

FluxMatrix Studio

Steady-state secondary clarifier solids-flux and state-point analysis for activated sludge systems.

Detailed visualization focus
Display units
Calculating…

01 · Geometry

Clarifier geometry

Area / weir
For rectangular geometry, blank uses 2 × (L + W). For circular geometry, blank uses π × D.

02 · Operating loads

Hydraulic and solids loading

Flows / concentrations
The selected settling correlation uses SVI in mL/g.

03 · Settling model

Vesilind correlation

v0 / k
The default SVI correlation is a screening approximation; site-specific settling test data are more reliable.

Output · Operating status

Results overview

Average case
Selected case status Safe / underloaded Waiting for calculation.
Average case Safe / underloaded
Peak case Unstable / overloaded
Limiting flux GL — kg/(m²·h)
Surface overflow rate — m/h
Solids loading SLR — kg/(m²·h)
Theoretical RAS concentration — mg/L
Smallest selected-case margin — Minimum of clarification / thickening margin

Primary visualization · SPA

State-point / flux plot

Gg / Gt / GL
Hover or focus a plotted marker for a numeric readout.

The active case is shown with solid curves and markers. The inactive case remains as a reference marker so average versus peak behavior can be compared without changing the input basis.

Condition view · Illustrative

Clarifier condition visualizer

—
Illustrative condition view based on current solids-loading and flux margins. Not a CFD model or a field blanket measurement replacement.
Influent → feedwell Effluent Effluent RAS withdrawal Center feedwell Clarified upper zone Sludge blanket Dense bottom solids
Load-ratio mapping pending. Clarification condition: pending. Blanket accumulation risk: pending.

The blanket fill is a deterministic visual mapping from Ga / GL only. V1 does not report a numeric sludge blanket depth.

Sensitivity scan · RAS

RAS operating window

0.20 → 1.50 Qr/Q

Deterministic scan for the selected operating case. Every point recomputes underflow velocity, total-flux limiting capacity, demand, margins, and status.

RAS operating window scan results
Qr / QQr (m³/h)Load ratioMinimum marginStatus

Review · Deterministic diagnostics

Diagnostics and recommendations

Screening flags

Warnings

  • No warnings yet.

Recommendations

  • No recommendations yet.

Traceability · Calculation record

Verification

A concise record of the current validated calculation basis.

Calculation statusPending
Selected caseAverage
Model / correlationDaigger-Roper (1985)
Verification availabilityAwaiting current result

Esta ferramenta de engenharia está disponível atualmente apenas em inglês.

01

Base de engenharia

Metodologia

A área de trabalho apresenta a resposta de cálculo aceita e preserva os casos de operação média e de pico declarados.

Triagem preliminar da separação de sólidos com velocidade de sedimentação, fluxo gravitacional e total, comportamento do ponto de estado, fluxo limite denso, estado de clarificação/adensamento e diagnósticos.

Normas / Base de referência

Secondary clarifier screeningSolids fluxPreliminary screening

Premissas

  • A avaliação preliminar usa a geometria da bacia e as cargas operacionais declaradas.
  • Unidades e identificadores de engenharia mantêm seu significado canônico.

Escopo / Limitações

  • Confirme o projeto final com dados do projeto, normas aplicáveis e revisão do engenheiro responsável.
02

Caminho de engenharia

Aplicação

  • Água municipal Água de origem, tratamento e decisões dos serviços de abastecimento.

Cenário

Fluxo de trabalho

  • Águas residuais Oito etapas de decisão da base e aceitação do afluente, pré-tratamento e tratamento primário até caminhos biológicos alternativos, separação secundária, polimento opcional, desinfecção e revisão final.
    Etapa 05 — Separação secundária de sólidosVoltar à etapa 05