Skip to main content
Volver a Herramientas

Herramienta de ingeniería · Utilidades

Perfil hidráulico de una planta de tratamiento de agua

Siga la línea piezométrica a través de segmentos de tubería, bombas, pérdidas fijas y límites de tanques introducidos por el usuario.

Estado
Disponible
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Sequential profile segments

Each segment uses only the fields shown for its selected type. Minimum HGL applies at the segment’s downstream station.

Segment 1
Segment 1
Segment 2
Segment 2
Segment 3
Segment 3
Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision c8d867d3

65 focused fixtures: Darcy–Weisbach reference fixture, laminar and turbulent factors, minor loss, pump and equipment steps, basin boundary, downstream criteria, optional elevation, and active type-specific input validation. Tests are deterministic and run without network access.

Esta herramienta de ingeniería está disponible actualmente solo en inglés.

01

Base de ingeniería

Metodología

Construye una línea de gradiente hidráulico secuencial con segmentos declarados de tubería, bomba, pérdida fija y límite de nivel de agua, usando Darcy–Weisbach y pérdidas menores ingresadas. Es un cribado HGL; omite cambios de carga de velocidad y no calcula EGL ni TDH.

Pipe velocity = Q/A; Reynolds number = vD/ν. Darcy factor uses f = 64/Re for laminar flow and Swamee–Jain for turbulent flow.

Major pipe loss uses Darcy–Weisbach; minor loss is ΣK·v²/(2g).

The sequential profile adds entered pump head and subtracts major, minor, and fixed equipment losses. A basin water surface is an explicit downstream HGL boundary.

Elevation is reported separately; pressure head where elevation is entered is downstream HGL minus elevation.

A segment minimum HGL criterion is evaluated once at its downstream station. The optional starting minimum HGL criterion is evaluated at the starting station.

For 2,000 < Re < 4,000, Swamee–Jain is used as a screening approximation and a transitional-flow warning is reported.

Alcance / Limitaciones

  • Calcule la fricción y las pérdidas menores, la HGL secuencial, la carga de presión, los criterios del usuario y el margen a partir de las propiedades hidráulicas declaradas.
  • No transient surge, looped network solution, pump selection, system-wide NPSH, or open-channel gradually varied flow.
  • No hydraulic grade is inferred from process-unit names. Basin water surfaces and minimum HGL criteria must be declared.
  • A margin below a user criterion is flagged for review but is not classified as safe or unsafe.
  • This screening HGL profile omits changes in velocity head between segments. It adds entered pump head directly to HGL and does not calculate the total energy grade line or total dynamic head (TDH).
  • Freeboard and available driving head are not calculated. No US-unit conversion path is implemented; hydraulic inputs and outputs use SI units.
02

Ruta de ingeniería

Contexto aguas arriba

  • Configuración y casos de diseño de toda la planta Use la disposición de procesos, casos de caudal y supuestos operativos declarados como contexto; esta herramienta apoya el diseño global y no es una etapa secuencial.

Decisión de esta herramienta

  • Perfil hidráulico de una planta de tratamiento de agua Siga la línea piezométrica a través de segmentos de tubería, bombas, pérdidas fijas y límites de tanques introducidos por el usuario.

Siguiente paso de ingeniería

  • Revisión de procesos unitarios e integrada Coordine este resultado global con el diseño de unidades y la revisión del proyecto; no implica una Etapa 07 ni una dependencia fija.

Flujo de trabajo