エンジニアリングツール · ユーティリティ

浄水場の水理縦断図設計

入力された配管、ポンプ、固定損失、池水面境界の各区間に沿って水理勾配線を追跡します。

状態
公開中
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Sequential profile segments

Each segment uses only the fields shown for its selected type. Minimum HGL applies at the segment’s downstream station.

Segment 1
Segment 1
Segment 2
Segment 2
Segment 3
Segment 3
Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision c8d867d3

65 focused fixtures: Darcy–Weisbach reference fixture, laminar and turbulent factors, minor loss, pump and equipment steps, basin boundary, downstream criteria, optional elevation, and active type-specific input validation. Tests are deterministic and run without network access.

このエンジニアリングツールは現在、英語版のみ提供しています。

01

エンジニアリングの根拠

方法

宣言された配管、ポンプ、固定損失、水面境界の区間から、Darcy–Weisbach と入力局部損失を用いて連続した水理勾配線を作成します。HGL のスクリーニングであり、速度水頭変化を省略し、EGL と TDH は計算しません。

Pipe velocity = Q/A; Reynolds number = vD/ν. Darcy factor uses f = 64/Re for laminar flow and Swamee–Jain for turbulent flow.

Major pipe loss uses Darcy–Weisbach; minor loss is ΣK·v²/(2g).

The sequential profile adds entered pump head and subtracts major, minor, and fixed equipment losses. A basin water surface is an explicit downstream HGL boundary.

Elevation is reported separately; pressure head where elevation is entered is downstream HGL minus elevation.

A segment minimum HGL criterion is evaluated once at its downstream station. The optional starting minimum HGL criterion is evaluated at the starting station.

For 2,000 < Re < 4,000, Swamee–Jain is used as a screening approximation and a transitional-flow warning is reported.

範囲 / 制限事項

  • 指定された水理特性から、管摩擦損失と局部損失、区間ごとの HGL、圧力水頭、ユーザー基準、余裕を計算します。
  • No transient surge, looped network solution, pump selection, system-wide NPSH, or open-channel gradually varied flow.
  • No hydraulic grade is inferred from process-unit names. Basin water surfaces and minimum HGL criteria must be declared.
  • A margin below a user criterion is flagged for review but is not classified as safe or unsafe.
  • This screening HGL profile omits changes in velocity head between segments. It adds entered pump head directly to HGL and does not calculate the total energy grade line or total dynamic head (TDH).
  • Freeboard and available driving head are not calculated. No US-unit conversion path is implemented; hydraulic inputs and outputs use SI units.
02

エンジニアリングパス

上流の前提

  • プラント全体の構成と設計ケース 宣言された工程構成、流量ケース、運転前提を背景として使用します。このツールは全体設計を支援し、連続する工程段階ではありません。

このツールでの設計判断

  • 浄水場の水理縦断図設計 入力された配管、ポンプ、固定損失、池水面境界の各区間に沿って水理勾配線を追跡します。

下流の設計ステップ

  • 単位プロセスと統合プロジェクトの確認 プラント全体の結果を単位プロセス設計とプロジェクトレビューに照合します。Stage 07 や固定された工程依存関係を示すものではありません。

ワークフロー

  • 都市飲料水の浄化 プラント全体の結果を単位プロセス設計とプロジェクトレビューに照合します。Stage 07 や固定された工程依存関係を示すものではありません。