Skip to main content
Retour à Outils

Outil d’ingénierie · Adsorption

Percée du GAC et durée de vie du lit

Calculez l’hydraulique du lit de GAC dans le navigateur et demandez au Worker des résultats autorisés de percée empirique ou de Yoon–Nelson.

Purification municipale de l’eau potableÉtape 04 — Oxydation ou adsorption
État
Disponible

PROJECT · OPTIONAL

Project metadata

01 · DESIGN BASIS

Bed hydraulics and breakthrough basis

Bed hydraulics inputs

Bed geometry is calculated here and remains available if the breakthrough calculation service is unavailable.

BED GEOMETRY & HYDRAULICS

Bed hydraulics

Calculated locally
Bed volume10m³
Carbon mass4,500kg
Empty-bed contact time6min
Superficial velocity20m/h

BREAKTHROUGH CALCULATION

Empirical breakthrough observations

Calculation service

Empirical observations

Enter measured or prepared observations. Values are sent only for the active method.

Time unit: BV
ObservationTime (BV)C/C0 (fraction)Action
1
2
3
4
5

Empirical observations require 0 ≤ C/C0 ≤ 1 and a nondecreasing curve when ordered by time.

The fit updates automatically after valid inputs stop changing.
Waiting for stable input.

02 · BREAKTHROUGH MODEL

Breakthrough estimate

Waiting for stable input.

03 · REPORTING

Exports

Cet outil d’ingénierie est actuellement disponible uniquement en anglais.

01

Base d’ingénierie

Méthodologie

Calcule la géométrie et l’hydraulique du lit à partir de la surface, de la profondeur, de la masse volumique apparente et du débit; le criblage de percée utilise une interpolation empirique bornée ou une régression de Yoon–Nelson. Il ne garantit pas la durée de vie à pleine échelle et n’effectue pas de conversion RSSCT automatique.

Bed volume = area × depth. Carbon mass = bed volume × user-entered bulk density. EBCT = bed volume / flow. Superficial velocity = flow / area.

Empirical mode interpolates only between adjacent observations; no extrapolation is used.

Yoon–Nelson mode fits ln(r/(1-r)) = k t - k τ by ordinary least squares and derives target time from the fitted model.

Bed-volume time converts to service time using entered bed volume and flow; hours convert to bed volumes using the same geometry and flow.

Périmètre / Limites

  • La géométrie du lit, la masse de charbon, l’EBCT et la vitesse superficielle restent calculés dans le navigateur. Les modèles de percée utilisent le Worker de référence ; l’interpolation empirique n’extrapole pas.
  • Breakthrough fitting and service-life estimates use the connected calculation service. If it is unavailable, no estimate is produced.
  • Yoon–Nelson does not model competitive adsorption, NOM fouling, mass-transfer-zone physics, or guaranteed field performance.
  • RSSCT scale-up advanced model: DEFERRED. No automatic RSSCT-to-full-scale conversion is performed.
  • Rotation planning basis is deferred; this version does not claim mechanistic lead/lag outlet prediction.
02

Parcours d’ingénierie

Contexte amont

  • Base de maîtrise des solides en amontConfirmez les hypothèses d’alimentation et de maîtrise des solides avant le criblage du média ou d’une barrière avancée.

Décision de cet outil

  • Percée du GAC et durée de vie du litCalculez l’hydraulique du lit de GAC dans le navigateur et demandez au Worker des résultats autorisés de percée empirique ou de Yoon–Nelson.