Outil d’ingénierie · Traitement de l’eau

Conception de la désinfection UV

Utilisez les points de capacité UVT fournis pour évaluer le nombre de réacteurs, les unités de secours et la puissance en fonctionnement.

Purification municipale de l’eau potableÉtape 05 — Disinfection
État
Disponible
PROJECT · OPTIONAL

Project metadata

Optional report context; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Leave this off for exact entered reference points. When on, document the source above and confirm it covers this reactor/model, target/reference dose, UVT basis, lamp/configuration, and operating envelope. ATLAS does not independently verify the source or interpolation rule.

Entered reactor performance/reference data

Enter two or more unique UVT points for one reactor at the entered reference dose. Rows can be entered in any order.

UVT (%)Entered reference flow capacity (m3/h/reactor)Remove

Use UVT values at the same wavelength and optical path length as the entered external reference data; EPA UVDGM commonly uses 254 nm and 1 cm. No absorbance or path-length conversion is applied. Each UVT must be greater than 0% and no more than 100%. Each entered reference flow capacity must be positive. Duplicate UVT values are rejected.

Runs locally in this browser from entered reactor performance/reference data.

02 · CALCULATED RESULT

Engineering results

Enter a design basis and reactor performance/reference data, then calculate a screening result.

03 · REPORTING

Exports and verification

Exports include the entered external reference basis, performance points, and calculated reactor sizing.

Verification suite

Calculation revision 1.2

58 focused fixtures: The focused UV suite covers entered-point sizing, reactor counts, optional power, point normalization, traceability, readable reports, and extrapolation guards; R1 authorization regressions are maintained in the Stage 05 audit suite..

Cet outil d’ingénierie est actuellement disponible uniquement en anglais.

01

Base d’ingénierie

Méthodologie

Dimensionne les réacteurs en service et de secours à partir de points externes UVT/capacité saisis, avec un point exact par défaut. L’interpolation n’est possible que si la source externe documentée l’autorise pour le réacteur et l’enveloppe d’exploitation concernés; aucune extrapolation ni dose réglementaire automatique.

At an exact design UVT match, capacity is taken from that exact entered reactor performance/reference point.

For an intermediate UVT, bounded linear interpolation is available only when the user confirms that the external validation/reference source permits this capacity relationship for the applicable reactor/model, target/reference dose, UVT basis, lamp/configuration basis, and operating envelope, and documents that source. This interpolation is user-authorized from entered external reference data; ATLAS does not independently validate it. No extrapolation is used.

EPA UV reactor validation is based on reactor-specific validated operating conditions. Dose/RED relationships with flow, UVT, lamp status/intensity, and other operating parameters depend on the reactor and validation method. ATLAS does not derive a generic UV dose-monitoring equation. Boundedness alone does not establish that linear interpolation is valid.

UVT values must use the same wavelength and optical path length as the entered external reference data; no absorbance or path-length conversion is applied.

Duty reactor count = ceiling(plant design flow / capacity per reactor from entered external reference data). Installed count = duty reactors + entered standby reactors.

Operating duty power = duty reactors x entered per-reactor electrical power. Standby reactors are not assumed energized.

The user-selected target dose must match the user-entered reference-dose value; neither dose value is calculated by this tool.

Périmètre / Limites

  • Un point de référence saisi exactement est utilisé par défaut. L’interpolation linéaire bornée n’est possible que si l’utilisateur documente son autorisation par une source externe. L’outil n’extrapole pas et n’établit pas de crédit de dose UV validé.
  • This is a screening calculation over user-entered reactor performance/reference data. The tool does not verify the external source or the entered data and does not establish regulatory UV dose credit.
  • Lamp power, flow, and UVT alone are not used to derive UV dose. The tool does not model reactor physics or CFD.
  • No theoretical fluence, RED, Validation Factor, pathogen dose requirement, organism-specific log inactivation, dose-monitoring equation, lamp/intensity physics, organism credit, manufacturer selection, or regulatory compliance logic is calculated.
  • Use the UVT wavelength and path length specified by the external source (EPA UVDGM examples commonly use 254 nm and 1 cm).
02

Parcours d’ingénierie

Contexte amont

  • Base de traitement avancé ciblé Ne retenez une barrière d’adsorption ou d’oxydation que si un objectif explicite de qualité d’eau la justifie.

Décision de cet outil

  • Conception de la désinfection UV Utilisez les points de capacité UVT fournis pour évaluer le nombre de réacteurs, les unités de secours et la puissance en fonctionnement.

Étape d’ingénierie en aval