GACの破過とろ床寿命設計

ブラウザーで GAC 層の水理を計算し、Worker に経験式または Yoon–Nelson による破過結果を要求します。

都市飲料水の浄化段階 04 — 酸化または吸着
状態
公開中

PROJECT · OPTIONAL

Project metadata

01 · DESIGN BASIS

Bed hydraulics and breakthrough basis

Bed hydraulics inputs

Bed geometry is calculated here and remains available if the breakthrough calculation service is unavailable.

BED GEOMETRY & HYDRAULICS

Bed hydraulics

Calculated locally
Bed volume10m³
Carbon mass4,500kg
Empty-bed contact time6min
Superficial velocity20m/h

BREAKTHROUGH CALCULATION

Empirical breakthrough observations

Calculation service

Empirical observations

Enter measured or prepared observations. Values are sent only for the active method.

Time unit: BV
ObservationTime (BV)C/C0 (fraction)Action
1
2
3
4
5

Empirical observations require 0 ≤ C/C0 ≤ 1 and a nondecreasing curve when ordered by time.

The fit updates automatically after valid inputs stop changing.
Waiting for stable input.

02 · BREAKTHROUGH MODEL

Breakthrough estimate

Waiting for stable input.

03 · REPORTING

Exports

このエンジニアリングツールは現在、英語版のみ提供しています。

01

エンジニアリングの根拠

方法

面積、深さ、かさ密度、流量から床層形状と水理を計算し、破過スクリーニングには範囲内の経験補間または Yoon–Nelson 回帰を使います。実規模の寿命を保証せず、RSSCT から実規模への自動換算も行いません。

Bed volume = area × depth. Carbon mass = bed volume × user-entered bulk density. EBCT = bed volume / flow. Superficial velocity = flow / area.

Empirical mode interpolates only between adjacent observations; no extrapolation is used.

Yoon–Nelson mode fits ln(r/(1-r)) = k t - k τ by ordinary least squares and derives target time from the fitted model.

Bed-volume time converts to service time using entered bed volume and flow; hours convert to bed volumes using the same geometry and flow.

範囲 / 制限事項

  • 層形状、炭素量、EBCT、表面速度はブラウザーで計算します。破過モデルは正式な Worker を使用し、経験式補間で外挿は行いません。
  • Breakthrough fitting and service-life estimates use the connected calculation service. If it is unavailable, no estimate is produced.
  • Yoon–Nelson does not model competitive adsorption, NOM fouling, mass-transfer-zone physics, or guaranteed field performance.
  • RSSCT scale-up advanced model: DEFERRED. No automatic RSSCT-to-full-scale conversion is performed.
  • Rotation planning basis is deferred; this version does not claim mechanistic lead/lag outlet prediction.
02

エンジニアリングパス

上流の前提

  • 選定された上流固形物管理の基準ろ材または高度処理バリアを評価する前に、供給水と固形物管理の前提を確認します。

このツールでの設計判断

  • GACの破過とろ床寿命設計ブラウザーで GAC 層の水理を計算し、Worker に経験式または Yoon–Nelson による破過結果を要求します。

下流の設計ステップ

  • 塩素・クロラミンのCT・残留濃度設計選択した消毒方式を貯留と最終水質確認に合わせます。スクリーニング結果は規制クレジットではありません。
  • UV消毒設計選択した消毒方式を貯留と最終水質確認に合わせます。スクリーニング結果は規制クレジットではありません。