Skip to main content
Voltar para Ferramentas

Ferramenta de engenharia · Adsorção

Ruptura do GAC e vida útil do leito

Calcule no navegador a hidráulica do leito de GAC e solicite ao Worker resultados autorizados de breakthrough empírico ou Yoon–Nelson.

Purificação municipal de água potávelEtapa 04 — Oxidação ou adsorção
Status
Disponível

PROJECT · OPTIONAL

Project metadata

01 · DESIGN BASIS

Bed hydraulics and breakthrough basis

Bed hydraulics inputs

Bed geometry is calculated here and remains available if the breakthrough calculation service is unavailable.

BED GEOMETRY & HYDRAULICS

Bed hydraulics

Calculated locally
Bed volume10m³
Carbon mass4,500kg
Empty-bed contact time6min
Superficial velocity20m/h

BREAKTHROUGH CALCULATION

Empirical breakthrough observations

Calculation service

Empirical observations

Enter measured or prepared observations. Values are sent only for the active method.

Time unit: BV
ObservationTime (BV)C/C0 (fraction)Action
1
2
3
4
5

Empirical observations require 0 ≤ C/C0 ≤ 1 and a nondecreasing curve when ordered by time.

The fit updates automatically after valid inputs stop changing.
Waiting for stable input.

02 · BREAKTHROUGH MODEL

Breakthrough estimate

Waiting for stable input.

03 · REPORTING

Exports

Esta ferramenta de engenharia está disponível atualmente apenas em inglês.

01

Base de engenharia

Metodologia

Calcula geometria e hidráulica do leito com área, profundidade, densidade aparente e vazão; a triagem de ruptura usa interpolação empírica limitada ou regressão de Yoon–Nelson. Não garante vida útil em escala plena nem faz conversão automática de RSSCT para escala plena.

Bed volume = area × depth. Carbon mass = bed volume × user-entered bulk density. EBCT = bed volume / flow. Superficial velocity = flow / area.

Empirical mode interpolates only between adjacent observations; no extrapolation is used.

Yoon–Nelson mode fits ln(r/(1-r)) = k t - k τ by ordinary least squares and derives target time from the fitted model.

Bed-volume time converts to service time using entered bed volume and flow; hours convert to bed volumes using the same geometry and flow.

Escopo / Limitações

  • Geometria do leito, massa de carvão, EBCT e velocidade superficial são calculadas no navegador. Os modelos de breakthrough usam o Worker autorizado; a interpolação empírica não extrapola.
  • Breakthrough fitting and service-life estimates use the connected calculation service. If it is unavailable, no estimate is produced.
  • Yoon–Nelson does not model competitive adsorption, NOM fouling, mass-transfer-zone physics, or guaranteed field performance.
  • RSSCT scale-up advanced model: DEFERRED. No automatic RSSCT-to-full-scale conversion is performed.
  • Rotation planning basis is deferred; this version does not claim mechanistic lead/lag outlet prediction.
02

Caminho de engenharia

Contexto a montante

  • Base selecionada de controle de sólidos a montanteConfirme as premissas da água de alimentação e do controle de sólidos antes de aplicar a triagem de meio ou barreira avançada.

Decisão desta ferramenta

  • Ruptura do GAC e vida útil do leitoCalcule no navegador a hidráulica do leito de GAC e solicite ao Worker resultados autorizados de breakthrough empírico ou Yoon–Nelson.

Próxima etapa de engenharia

  • CT e residual de cloro/cloraminasCoordene a desinfecção selecionada com armazenamento e qualidade final; um resultado de triagem não é crédito regulatório.
  • Projeto de desinfecção UVCoordene a desinfecção selecionada com armazenamento e qualidade final; um resultado de triagem não é crédito regulatório.