Skip to main content
돌아가기: 도구

엔지니어링 도구 · 수처리

정수장 물 및 물질수지

공정, 폐수와 선언된 재순환 흐름을 포함해 플랜트 전체의 정상상태 물·성분 수지를 풉니다.

상태
사용 가능
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Name each process, declare product and waste-side recycle fractions, and choose a same-process or upstream recycle destination.

Coagulation & Conditioning
Coagulation & Conditioning
Clarification
Clarification
Granular Media Filtration
Granular Media Filtration
Clearwell
Clearwell
Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision 6ed6a0c4

68 focused fixtures: one-loop fixture, named upstream recycle, inactive recycle targets, mass order, closure, fraction validation, matrix singularity, and structured export contracts. Tests are deterministic and run without network access.

이 엔지니어링 도구는 현재 영어로만 제공됩니다.

01

엔지니어링 근거

방법론

입력된 공정 분율, 제거량, 추가량, 동일 또는 상류 공정으로의 재순환으로 선언된 정상상태 물 및 성분 수지를 풉니다. 물과 성분의 폐합 오차를 각각 명시하며 폐합을 강제하기 위해 유량이나 질량을 정규화하지 않습니다.

The steady-state water network is written as F = b + A F and solved with deterministic pivoted Gauss-Jordan elimination.

Each process forwards its declared fraction of inlet flow to the next process. At the final process, forward flow is the final product stream.

The remainder is the waste-side flow. The entered recycle fraction applies to this waste split and returns only to the same process or an upstream process.

Constituent mass flow is water flow multiplied by concentration with unit conversion. At each node, removal is applied to inlet constituent mass, then the entered addition is applied, then the outlet constituent mass is split using the water-flow fractions.

Accumulation is assumed to be zero at steady state. Water and constituent closure errors are reported separately. Errors within the documented tolerance are reported as zero; the flows and masses are not normalized to force closure.

Water closure tolerance is max(1e-8 m³/d, external feed × 1e-10); constituent mass tolerance is max(1e-8 kg/d, (external mass + entered additions) × 1e-10).

범위 / 제한사항

  • 입력된 공정 분율로 필요한 공정 유입, 최종 제품수, 폐수와 수지 폐합을 검토합니다. 제품이 없는 말단 사례와 미해결 하류 입력도 명시합니다.
  • This is a compact steady-state process train, not a general graphical or dynamic simulator.
  • No process-selection model, reaction chemistry, equilibrium, or kinetics are predicted. Removal and addition are user-entered.
  • Recycle is limited to the same process or an upstream process. Downstream bypass or side-stream routing is not represented.
  • The loaded example values are synthetic and do not represent a required treatment train.
  • Near-singular systems and negative or nonfinite solved flows are rejected.
  • Only SI flow units (m³/d) and constituent mass units (kg/d) are implemented. MGD and gpm conversion paths are not available.
02

엔지니어링 경로

상류 맥락

  • 플랜트 전체 구성과 설계 사례 선언된 공정 배치, 유량 사례, 운전 가정을 맥락으로 사용합니다. 이 도구는 전체 플랜트 설계를 지원하며 순차 단계가 아닙니다.

현재 도구의 설계 결정

  • 정수장 물 및 물질수지 공정, 폐수와 선언된 재순환 흐름을 포함해 플랜트 전체의 정상상태 물·성분 수지를 풉니다.

하류 엔지니어링 단계

  • 단위 공정 및 통합 프로젝트 검토 플랜트 전체 결과를 단위 공정 설계와 프로젝트 검토에 연계합니다. Stage 07이나 고정된 공정 의존성을 뜻하지 않습니다.

워크플로

  • 도시 상수도 정수 플랜트 전체 결과를 단위 공정 설계와 프로젝트 검토에 연계합니다. Stage 07이나 고정된 공정 의존성을 뜻하지 않습니다.