Skip to main content
Zurück zu Rechner

Ingenieurwerkzeug · Wasseraufbereitung

Anlagenweite Wasser- und Stoffbilanz

Lösen Sie eine stationäre Anlagenbilanz für Wasser und Inhaltsstoffe über Prozesse, Abwasser und deklarierte Rückführströme.

Status
Verfügbar
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Name each process, declare product and waste-side recycle fractions, and choose a same-process or upstream recycle destination.

Coagulation & Conditioning
Coagulation & Conditioning
Clarification
Clarification
Granular Media Filtration
Granular Media Filtration
Clearwell
Clearwell
Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision 6ed6a0c4

68 focused fixtures: one-loop fixture, named upstream recycle, inactive recycle targets, mass order, closure, fraction validation, matrix singularity, and structured export contracts. Tests are deterministic and run without network access.

Dieses Engineering-Tool ist derzeit nur in englischer Sprache verfügbar.

01

Ingenieurtechnische Grundlage

Methodik

Löst die deklarierte stationäre Wasser- und Stoffbilanz aus eingegebenen Prozessanteilen, Entfernungen, Zugaben und Rückläufen in denselben oder einen vorgelagerten Prozess. Wasser- und Stoffbilanzfehler werden explizit ausgewiesen; Durchflüsse und Massen werden nicht zur erzwungenen Schließung normalisiert.

The steady-state water network is written as F = b + A F and solved with deterministic pivoted Gauss-Jordan elimination.

Each process forwards its declared fraction of inlet flow to the next process. At the final process, forward flow is the final product stream.

The remainder is the waste-side flow. The entered recycle fraction applies to this waste split and returns only to the same process or an upstream process.

Constituent mass flow is water flow multiplied by concentration with unit conversion. At each node, removal is applied to inlet constituent mass, then the entered addition is applied, then the outlet constituent mass is split using the water-flow fractions.

Accumulation is assumed to be zero at steady state. Water and constituent closure errors are reported separately. Errors within the documented tolerance are reported as zero; the flows and masses are not normalized to force closure.

Water closure tolerance is max(1e-8 m³/d, external feed × 1e-10); constituent mass tolerance is max(1e-8 kg/d, (external mass + entered additions) × 1e-10).

Umfang / Grenzen

  • Prüfen Sie erforderlichen Prozesszulauf, Endprodukt, Abwasser und Bilanzschluss anhand der eingegebenen Prozessanteile. Fälle ohne Endprodukt sowie ungelöste nachgelagerte Eingaben bleiben ausdrücklich sichtbar.
  • This is a compact steady-state process train, not a general graphical or dynamic simulator.
  • No process-selection model, reaction chemistry, equilibrium, or kinetics are predicted. Removal and addition are user-entered.
  • Recycle is limited to the same process or an upstream process. Downstream bypass or side-stream routing is not represented.
  • The loaded example values are synthetic and do not represent a required treatment train.
  • Near-singular systems and negative or nonfinite solved flows are rejected.
  • Only SI flow units (m³/d) and constituent mass units (kg/d) are implemented. MGD and gpm conversion paths are not available.
02

Ingenieurpfad

Vorgelagerter Kontext

  • Anlagenweite Prozesskonfiguration und Auslegungsfälle Nutzen Sie erklärte Prozessanordnung, Durchflussfälle und Betriebsannahmen als Kontext; dieses Werkzeug unterstützt die Gesamtanlage und ist keine sequenzielle Stufe.

Entscheidung dieses Werkzeugs

  • Anlagenweite Wasser- und Stoffbilanz Lösen Sie eine stationäre Anlagenbilanz für Wasser und Inhaltsstoffe über Prozesse, Abwasser und deklarierte Rückführströme.

Nachgelagerter Engineering-Schritt

  • Einzelprozess- und integrierte Projektprüfung Stimmen Sie das anlagenweite Ergebnis mit Einheitsauslegung und Projektprüfung ab; es entsteht weder eine Stufe 07 noch eine feste Prozessabhängigkeit.

Arbeitsablauf

  • Kommunale Trinkwasseraufbereitung Stimmen Sie das anlagenweite Ergebnis mit Einheitsauslegung und Projektprüfung ab; es entsteht weder eine Stufe 07 noch eine feste Prozessabhängigkeit.