浄水場の水量・物質収支

工程、廃水、指定した返送流を含むプラント全体の定常水量・成分収支を解きます。

状態
公開中
PROJECT · OPTIONAL

Project metadata

Report context for exports; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Name each process, declare product and waste-side recycle fractions, and choose a same-process or upstream recycle destination.

Coagulation & Conditioning
Coagulation & Conditioning
Clarification
Clarification
Granular Media Filtration
Granular Media Filtration
Clearwell
Clearwell
Engineering calculations run locally in this browser after assets load.

02 · CALCULATED RESULT

Results at a glance

Load or enter inputs, then calculate to create an authoritative result.

03 · REPORTING

Exports and verification

CSV contains input and output detail. PDF uses the current calculation and report metadata.

Verification suite

Calculation revision 6ed6a0c4

68 focused fixtures: one-loop fixture, named upstream recycle, inactive recycle targets, mass order, closure, fraction validation, matrix singularity, and structured export contracts. Tests are deterministic and run without network access.

このエンジニアリングツールは現在、英語版のみ提供しています。

01

エンジニアリングの根拠

方法

入力された工程分配、除去、添加、および同一工程または上流工程への返送を用いて、宣言された定常水量・成分収支を解きます。水量と成分の閉合誤差を明示して報告し、閉合を強制するための正規化は行いません。

The steady-state water network is written as F = b + A F and solved with deterministic pivoted Gauss-Jordan elimination.

Each process forwards its declared fraction of inlet flow to the next process. At the final process, forward flow is the final product stream.

The remainder is the waste-side flow. The entered recycle fraction applies to this waste split and returns only to the same process or an upstream process.

Constituent mass flow is water flow multiplied by concentration with unit conversion. At each node, removal is applied to inlet constituent mass, then the entered addition is applied, then the outlet constituent mass is split using the water-flow fractions.

Accumulation is assumed to be zero at steady state. Water and constituent closure errors are reported separately. Errors within the documented tolerance are reported as zero; the flows and masses are not normalized to force closure.

Water closure tolerance is max(1e-8 m³/d, external feed × 1e-10); constituent mass tolerance is max(1e-8 kg/d, (external mass + entered additions) × 1e-10).

範囲 / 制限事項

  • 入力された工程比率から、必要な工程流入、最終製品水、廃水、収支閉合を確認します。製品水がゼロとなる終端ケースや未解決の下流入力も明示します。
  • This is a compact steady-state process train, not a general graphical or dynamic simulator.
  • No process-selection model, reaction chemistry, equilibrium, or kinetics are predicted. Removal and addition are user-entered.
  • Recycle is limited to the same process or an upstream process. Downstream bypass or side-stream routing is not represented.
  • The loaded example values are synthetic and do not represent a required treatment train.
  • Near-singular systems and negative or nonfinite solved flows are rejected.
  • Only SI flow units (m³/d) and constituent mass units (kg/d) are implemented. MGD and gpm conversion paths are not available.
02

エンジニアリングパス

上流の前提

  • プラント全体の構成と設計ケース 宣言された工程構成、流量ケース、運転前提を背景として使用します。このツールは全体設計を支援し、連続する工程段階ではありません。

このツールでの設計判断

  • 浄水場の水量・物質収支 工程、廃水、指定した返送流を含むプラント全体の定常水量・成分収支を解きます。

下流の設計ステップ

  • 単位プロセスと統合プロジェクトの確認 プラント全体の結果を単位プロセス設計とプロジェクトレビューに照合します。Stage 07 や固定された工程依存関係を示すものではありません。

ワークフロー

  • 都市飲料水の浄化 プラント全体の結果を単位プロセス設計とプロジェクトレビューに照合します。Stage 07 や固定された工程依存関係を示すものではありません。