Établissez la base de conditionnement et de précipitation industrielle à partir des données déclarées de titrage, dose, élimination et provenance. Préparez les besoins chimiques, les solides modélisés et le transfert vers la séparation sans prédire les performances.

État
Disponible

ENGINEERING WORKBENCH · WASTEWATER STAGE 03

Industrial conditioning and separation-feed basis

Explicit project, laboratory, vendor, and observed inputs. No chemical optimum or treatment performance is inferred.

Manual workflow pathWastewater Preliminary Treatment → Stage 03 physicochemical conditioning → clarifier / vendor separation → Activated Sludge or a selected alternative.Wastewater Preliminary TreatmentActivated SludgeOxyMatrix

01 · FLOW AND PROJECT BASIS

Design flow cases

Cases retain their own time basis; event and peak cases are never annualized.
Average flow provenance
Maximum Day and Peak Hour provenance
Maximum Day Flow provenance · optional
Peak Hour Flow provenance · optional

Bounded event / batch

02 · NEUTRALIZATION BASIS

Chemical demand requires a defined equivalent basis

pH difference alone never calculates reagent demand.
pH observations / target provenance · optional
Neutralization dose provenance

03 · COAGULATION / FLOCCULATION

Use declared test, vendor, or project doses

ATLAS does not infer an optimum dose from TSS, COD, BOD₅, or turbidity.
Coagulation / flocculation dose provenance

Declared mix / flocculation HRT

V = Q × t · no universal HRT is assumed.
Rapid-mix HRT provenance
Flocculation HRT provenance

04 · CHEMICAL PRECIPITATION

Choose explicit reaction or declared dose authority

Stoichiometric reagent availability does not guarantee complete precipitation.
Defined reactionFeCl₃ + PO₄³⁻ → FePO₄(s) + 3 Cl⁻Orthophosphate target is expressed as mg/L as P. Stoichiometry applies only to the declared captured P mass; no equilibrium/speciation or removal prediction.

Optional reaction/contact volume

Declared flow and HRT only.
Reaction/contact HRT provenance · optional

05 · MODELED CONSTITUENT BALANCE

Preserve constituent identity, sample basis and provenance

No default removal percentages; each declared capture is separate from reagent mass.

Enter concentrations in mg/L or mg/L as P as identified. A case requires a paired flow before any mass load is calculated. “No removal declared” is pass-through component accounting only.

Total suspended solidstss · SUSPENDED_SOLIDS
Average Daily Flow
Total suspended solids declared removal provenance
Maximum Day Flow
Total suspended solids declared removal provenance
Peak Hour Flow
Orthophosphate-PorthophosphateP · PRECIPITATION_TARGET
Average Daily Flow
Orthophosphate-P declared removal provenance
Maximum Day Flow
Orthophosphate-P declared removal provenance
Peak Hour Flow
Orthophosphate-P declared removal provenance

06 · CHEMICAL DEMAND

Average, maximum-day, peak-feed, and event quantities

No peak-hour or event annualization.

Chemical feed package by explicit flow case

Flow case / chemicalActive doseActive demandPeak-equivalent basisProduct massProduct volumeBasis
Calculate to populate this result table.

Maximum Day is a design-day quantity. Peak Hour is actual kg/h (and may show separately labelled kg/d-equivalent); Event is kg/event. Average daily use is not annualized without an operating-days basis.

Manual feed package handoff: Chemical Feed & Storage Designer owns storage, day-tank, feed-pump redundancy, and turndown sizing.

07 · MODELED COMPONENT CLOSURE

Declared influent, captured, and remaining liquid mass

Not a whole-plant mass balance; chemical reagent is an added mass term.

MODELED_COMPONENT_CLOSURE

Constituent / caseInfluent massDeclared captured / precipitatedRemaining liquid loadClosure
Calculate to populate this result table.
Stream contractPHYSICOCHEMICAL_INFLUENT → CONDITIONED_WASTEWATER → SEPARATION_FEED. PHYSICOCHEMICAL_EFFLUENT_BASIS is declared/project basis only; this product does not predict effluent quality.

08 · CHEMICAL SOLIDS

Separate captured solids from reaction solids

Wet sludge volume requires declared dry-solids concentration and density.
Optional chemical-solids provenance
Coagulant hydroxide solids ratio provenance · optional
Reagent insolubles ratio provenance · optional
Other chemical solids provenance · optional

Modeled dry solids ledger

Flow caseCaptured influent suspended solidsPrecipitated target constituent · informationalReaction product solidsCoagulant hydroxideReagent insolublesOther declared solidsTotal modeled dry solidsIdentity
Calculate to populate this result table.

PHYSICOCHEMICAL_SLUDGE_BASIS is distinct from PRIMARY_SLUDGE, BIOLOGICAL_WAS, SCREENINGS, and GRIT. Precipitated target mass is informational when included in reaction-product solids.

09 · DOWNSTREAM SEPARATION HANDOFF

Package the declared separation feed

Clarifier and DAF sizing remain outside this product.
Sludge solids concentration provenance · optional
Sludge density provenance · optional

10 · DETAILED RESULTS

Review the current result package

Calculated values remain separated from their declared or reference-supported bases.

Mix / reaction volume basis

Process zoneFlow caseDeclared HRTCalculated volumeProvenance
Calculate to populate this result table.

Flow-case calculation summary

Flow caseHydraulic basisChemical quantity basisModeled dry solidsState
Calculate to populate this result table.

Cet outil d’ingénierie est actuellement disponible uniquement en anglais.

01

Base d’ingénierie

Méthodologie

Établissez la base de conditionnement et de précipitation industrielle à partir des données déclarées de titrage, dose, élimination et provenance. Préparez les besoins chimiques, les solides modélisés et le transfert vers la séparation sans prédire les performances.

Hypothèses

  • Prend en charge des méthodes explicites de neutralisation, une dose et un temps de séjour déclarés pour la coagulation/floculation, un cas stœchiométrique limité FeCl₃/orthophosphate-P ou des rapports de réactif déclarés, la fermeture des composants, les solides chimiques et un transfert manuel vers un clarificateur ou un système de séparation de projet. Ne prédit ni dose optimale, ni spéciation, ni rendement d’élimination, ni toxicité, biodégradabilité, conformité réglementaire, dimensionnement DAF ou équipements de stockage/alimentation chimique.

Périmètre / Limites

  • Prend en charge des méthodes explicites de neutralisation, une dose et un temps de séjour déclarés pour la coagulation/floculation, un cas stœchiométrique limité FeCl₃/orthophosphate-P ou des rapports de réactif déclarés, la fermeture des composants, les solides chimiques et un transfert manuel vers un clarificateur ou un système de séparation de projet. Ne prédit ni dose optimale, ni spéciation, ni rendement d’élimination, ni toxicité, biodégradabilité, conformité réglementaire, dimensionnement DAF ou équipements de stockage/alimentation chimique.
02

Parcours d’ingénierie

Contexte amont

  • Base de conception de l’influent des eaux usées Établissez la base de conditionnement et de précipitation industrielle à partir des données déclarées de titrage, dose, élimination et provenance. Préparez les besoins chimiques, les solides modélisés et le transfert vers la séparation sans prédire les performances.
  • Concepteur du prétraitement des eaux usées Établissez la base de conditionnement et de précipitation industrielle à partir des données déclarées de titrage, dose, élimination et provenance. Préparez les besoins chimiques, les solides modélisés et le transfert vers la séparation sans prédire les performances.

Décision de cet outil

  • Concepteur du prétraitement physicochimique industriel Établissez la base de conditionnement et de précipitation industrielle à partir des données déclarées de titrage, dose, élimination et provenance. Préparez les besoins chimiques, les solides modélisés et le transfert vers la séparation sans prédire les performances.

Étape d’ingénierie en aval

  • Conception des clarificateurs Prend en charge des méthodes explicites de neutralisation, une dose et un temps de séjour déclarés pour la coagulation/floculation, un cas stœchiométrique limité FeCl₃/orthophosphate-P ou des rapports de réactif déclarés, la fermeture des composants, les solides chimiques et un transfert manuel vers un clarificateur ou un système de séparation de projet. Ne prédit ni dose optimale, ni spéciation, ni rendement d’élimination, ni toxicité, biodégradabilité, conformité réglementaire, dimensionnement DAF ou équipements de stockage/alimentation chimique.
  • Concepteur de Boues Activées Établissez la base de conditionnement et de précipitation industrielle à partir des données déclarées de titrage, dose, élimination et provenance. Préparez les besoins chimiques, les solides modélisés et le transfert vers la séparation sans prédire les performances.