Skip to main content
戻る: ツール

エンジニアリングツール · 排水処理

産業排水の物理化学前処理設計

申告された滴定、薬注量、除去率、出典情報に基づき、産業排水の調整・沈殿処理の設計基準を作成します。薬品需要、モデル化した固形物、下流分離への引継ぎを整理し、処理性能は予測しません。

状態
公開中

ENGINEERING WORKBENCH · WASTEWATER STAGE 03

Industrial conditioning and separation-feed basis

Explicit project, laboratory, vendor, and observed inputs. No chemical optimum or treatment performance is inferred.

Manual workflow pathWastewater Preliminary Treatment → Stage 03 physicochemical conditioning → clarifier / vendor separation → Activated Sludge or a selected alternative.Wastewater Preliminary TreatmentActivated SludgeOxyMatrix

01 · FLOW AND PROJECT BASIS

Design flow cases

Cases retain their own time basis; event and peak cases are never annualized.
Average flow provenance
Maximum Day and Peak Hour provenance
Maximum Day Flow provenance · optional
Peak Hour Flow provenance · optional

Bounded event / batch

02 · NEUTRALIZATION BASIS

Chemical demand requires a defined equivalent basis

pH difference alone never calculates reagent demand.
pH observations / target provenance · optional
Neutralization dose provenance

03 · COAGULATION / FLOCCULATION

Use declared test, vendor, or project doses

ATLAS does not infer an optimum dose from TSS, COD, BOD₅, or turbidity.
Coagulation / flocculation dose provenance

Declared mix / flocculation HRT

V = Q × t · no universal HRT is assumed.
Rapid-mix HRT provenance
Flocculation HRT provenance

04 · CHEMICAL PRECIPITATION

Choose explicit reaction or declared dose authority

Stoichiometric reagent availability does not guarantee complete precipitation.
Defined reactionFeCl₃ + PO₄³⁻ → FePO₄(s) + 3 Cl⁻Orthophosphate target is expressed as mg/L as P. Stoichiometry applies only to the declared captured P mass; no equilibrium/speciation or removal prediction.

Optional reaction/contact volume

Declared flow and HRT only.
Reaction/contact HRT provenance · optional

05 · MODELED CONSTITUENT BALANCE

Preserve constituent identity, sample basis and provenance

No default removal percentages; each declared capture is separate from reagent mass.

Enter concentrations in mg/L or mg/L as P as identified. A case requires a paired flow before any mass load is calculated. “No removal declared” is pass-through component accounting only.

Total suspended solidstss · SUSPENDED_SOLIDS
Average Daily Flow
Total suspended solids declared removal provenance
Maximum Day Flow
Total suspended solids declared removal provenance
Peak Hour Flow
Orthophosphate-PorthophosphateP · PRECIPITATION_TARGET
Average Daily Flow
Orthophosphate-P declared removal provenance
Maximum Day Flow
Orthophosphate-P declared removal provenance
Peak Hour Flow
Orthophosphate-P declared removal provenance

06 · CHEMICAL DEMAND

Average, maximum-day, peak-feed, and event quantities

No peak-hour or event annualization.

Chemical feed package by explicit flow case

Flow case / chemicalActive doseActive demandPeak-equivalent basisProduct massProduct volumeBasis
Calculate to populate this result table.

Maximum Day is a design-day quantity. Peak Hour is actual kg/h (and may show separately labelled kg/d-equivalent); Event is kg/event. Average daily use is not annualized without an operating-days basis.

Manual feed package handoff: Chemical Feed & Storage Designer owns storage, day-tank, feed-pump redundancy, and turndown sizing.

07 · MODELED COMPONENT CLOSURE

Declared influent, captured, and remaining liquid mass

Not a whole-plant mass balance; chemical reagent is an added mass term.

MODELED_COMPONENT_CLOSURE

Constituent / caseInfluent massDeclared captured / precipitatedRemaining liquid loadClosure
Calculate to populate this result table.
Stream contractPHYSICOCHEMICAL_INFLUENT → CONDITIONED_WASTEWATER → SEPARATION_FEED. PHYSICOCHEMICAL_EFFLUENT_BASIS is declared/project basis only; this product does not predict effluent quality.

08 · CHEMICAL SOLIDS

Separate captured solids from reaction solids

Wet sludge volume requires declared dry-solids concentration and density.
Optional chemical-solids provenance
Coagulant hydroxide solids ratio provenance · optional
Reagent insolubles ratio provenance · optional
Other chemical solids provenance · optional

Modeled dry solids ledger

Flow caseCaptured influent suspended solidsPrecipitated target constituent · informationalReaction product solidsCoagulant hydroxideReagent insolublesOther declared solidsTotal modeled dry solidsIdentity
Calculate to populate this result table.

PHYSICOCHEMICAL_SLUDGE_BASIS is distinct from PRIMARY_SLUDGE, BIOLOGICAL_WAS, SCREENINGS, and GRIT. Precipitated target mass is informational when included in reaction-product solids.

09 · DOWNSTREAM SEPARATION HANDOFF

Package the declared separation feed

Clarifier and DAF sizing remain outside this product.
Sludge solids concentration provenance · optional
Sludge density provenance · optional

10 · DETAILED RESULTS

Review the current result package

Calculated values remain separated from their declared or reference-supported bases.

Mix / reaction volume basis

Process zoneFlow caseDeclared HRTCalculated volumeProvenance
Calculate to populate this result table.

Flow-case calculation summary

Flow caseHydraulic basisChemical quantity basisModeled dry solidsState
Calculate to populate this result table.

このエンジニアリングツールは現在、英語版のみ提供しています。

01

エンジニアリングの根拠

方法

申告された滴定、薬注量、除去率、出典情報に基づき、産業排水の調整・沈殿処理の設計基準を作成します。薬品需要、モデル化した固形物、下流分離への引継ぎを整理し、処理性能は予測しません。

前提

  • 明示された中和方法、申告された凝集・フロック形成の薬注量と滞留時間、限定的な FeCl₃/オルトリン酸-P 化学量論ケースまたは申告された薬剤比、成分収支、化学固形物、澄明池またはプロジェクト分離設備への手動引継ぎに対応します。最適薬注量、化学種、除去性能、毒性、生分解性、規制適合、DAF 寸法、薬品貯蔵・供給設備は予測・設計しません。

範囲 / 制限事項

  • 明示された中和方法、申告された凝集・フロック形成の薬注量と滞留時間、限定的な FeCl₃/オルトリン酸-P 化学量論ケースまたは申告された薬剤比、成分収支、化学固形物、澄明池またはプロジェクト分離設備への手動引継ぎに対応します。最適薬注量、化学種、除去性能、毒性、生分解性、規制適合、DAF 寸法、薬品貯蔵・供給設備は予測・設計しません。
02

エンジニアリングパス

上流の前提

  • 廃水流入水の設計基準 申告された滴定、薬注量、除去率、出典情報に基づき、産業排水の調整・沈殿処理の設計基準を作成します。薬品需要、モデル化した固形物、下流分離への引継ぎを整理し、処理性能は予測しません。
  • 排水前処理設計ツール 申告された滴定、薬注量、除去率、出典情報に基づき、産業排水の調整・沈殿処理の設計基準を作成します。薬品需要、モデル化した固形物、下流分離への引継ぎを整理し、処理性能は予測しません。

このツールでの設計判断

  • 産業排水の物理化学前処理設計 申告された滴定、薬注量、除去率、出典情報に基づき、産業排水の調整・沈殿処理の設計基準を作成します。薬品需要、モデル化した固形物、下流分離への引継ぎを整理し、処理性能は予測しません。

下流の設計ステップ

  • 沈殿池設計 明示された中和方法、申告された凝集・フロック形成の薬注量と滞留時間、限定的な FeCl₃/オルトリン酸-P 化学量論ケースまたは申告された薬剤比、成分収支、化学固形物、澄明池またはプロジェクト分離設備への手動引継ぎに対応します。最適薬注量、化学種、除去性能、毒性、生分解性、規制適合、DAF 寸法、薬品貯蔵・供給設備は予測・設計しません。
  • 活性汚泥設計ツール 申告された滴定、薬注量、除去率、出典情報に基づき、産業排水の調整・沈殿処理の設計基準を作成します。薬品需要、モデル化した固形物、下流分離への引継ぎを整理し、処理性能は予測しません。