Ferramenta de engenharia · Tratamento de água

Projeto de desinfecção UV

Use pontos de referência de capacidade UVT informados pelo usuário para avaliar quantidade de reatores, unidades de reserva e potência operacional.

Purificação municipal de água potávelEtapa 05 — Disinfection
Status
Disponível
PROJECT · OPTIONAL

Project metadata

Optional report context; it does not change calculations.Edit detailsHide details

01 · USER INPUT

Design basis and inputs

Leave this off for exact entered reference points. When on, document the source above and confirm it covers this reactor/model, target/reference dose, UVT basis, lamp/configuration, and operating envelope. ATLAS does not independently verify the source or interpolation rule.

Entered reactor performance/reference data

Enter two or more unique UVT points for one reactor at the entered reference dose. Rows can be entered in any order.

UVT (%)Entered reference flow capacity (m3/h/reactor)Remove

Use UVT values at the same wavelength and optical path length as the entered external reference data; EPA UVDGM commonly uses 254 nm and 1 cm. No absorbance or path-length conversion is applied. Each UVT must be greater than 0% and no more than 100%. Each entered reference flow capacity must be positive. Duplicate UVT values are rejected.

Runs locally in this browser from entered reactor performance/reference data.

02 · CALCULATED RESULT

Engineering results

Enter a design basis and reactor performance/reference data, then calculate a screening result.

03 · REPORTING

Exports and verification

Exports include the entered external reference basis, performance points, and calculated reactor sizing.

Verification suite

Calculation revision 1.2

58 focused fixtures: The focused UV suite covers entered-point sizing, reactor counts, optional power, point normalization, traceability, readable reports, and extrapolation guards; R1 authorization regressions are maintained in the Stage 05 audit suite..

Esta ferramenta de engenharia está disponível atualmente apenas em inglês.

01

Base de engenharia

Metodologia

Dimensiona reatores de serviço e reserva com pontos externos informados de UVT/capacidade, usando um ponto exato por padrão. A interpolação só é permitida quando a fonte externa documentada a autoriza para o reator e a faixa operacional aplicáveis; não extrapola nem concede crédito regulatório automático de dose.

At an exact design UVT match, capacity is taken from that exact entered reactor performance/reference point.

For an intermediate UVT, bounded linear interpolation is available only when the user confirms that the external validation/reference source permits this capacity relationship for the applicable reactor/model, target/reference dose, UVT basis, lamp/configuration basis, and operating envelope, and documents that source. This interpolation is user-authorized from entered external reference data; ATLAS does not independently validate it. No extrapolation is used.

EPA UV reactor validation is based on reactor-specific validated operating conditions. Dose/RED relationships with flow, UVT, lamp status/intensity, and other operating parameters depend on the reactor and validation method. ATLAS does not derive a generic UV dose-monitoring equation. Boundedness alone does not establish that linear interpolation is valid.

UVT values must use the same wavelength and optical path length as the entered external reference data; no absorbance or path-length conversion is applied.

Duty reactor count = ceiling(plant design flow / capacity per reactor from entered external reference data). Installed count = duty reactors + entered standby reactors.

Operating duty power = duty reactors x entered per-reactor electrical power. Standby reactors are not assumed energized.

The user-selected target dose must match the user-entered reference-dose value; neither dose value is calculated by this tool.

Escopo / Limitações

  • Por padrão, usa-se um ponto de referência informado exatamente. A interpolação linear limitada só é permitida se o usuário documentar a autorização da fonte externa. Não há extrapolação nem crédito de dose UV validado.
  • This is a screening calculation over user-entered reactor performance/reference data. The tool does not verify the external source or the entered data and does not establish regulatory UV dose credit.
  • Lamp power, flow, and UVT alone are not used to derive UV dose. The tool does not model reactor physics or CFD.
  • No theoretical fluence, RED, Validation Factor, pathogen dose requirement, organism-specific log inactivation, dose-monitoring equation, lamp/intensity physics, organism credit, manufacturer selection, or regulatory compliance logic is calculated.
  • Use the UVT wavelength and path length specified by the external source (EPA UVDGM examples commonly use 254 nm and 1 cm).
02

Caminho de engenharia

Contexto a montante

  • Base de tratamento avançado direcionado Só avance com adsorção ou oxidação quando um objetivo específico de qualidade da água justificar essa barreira.

Decisão desta ferramenta

  • Projeto de desinfecção UV Use pontos de referência de capacidade UVT informados pelo usuário para avaliar quantidade de reatores, unidades de reserva e potência operacional.

Próxima etapa de engenharia