Skip to main content
返回 计算工具

工程工具 · 废水处理

污水进水设计基础

为下游污水处理设计建立水力、浓度和质量负荷基础。

状态
已上线
UnavailableEnter average daily flow and at least one concentration.
Display
01

Project / basis

Identify this influent basis

Project details appear in the report and do not change the calculation.

Additional report details and interpretation

Interpretation context only. It does not create permit logic or effluent targets.

References appear only when sample point, process declaration, case, and sampling basis are compatible. They are not acceptance criteria.

02

Hydraulic basis

Average and peak flow

Start with average daily flow. Maximum-day, peak-hour, and minimum flows are optional.

Required. Canonical basis: m³/d.

Average flow period and location
Optional maximum-day, peak-hour, and minimum flows

For each case, choose either a direct flow or a factor. Only the selected input is shown.

Maximum-day flow

Optional · canonical m³/d

Peak-hour flow

Optional · canonical m³/h

The declared interval remains one peak hour, even when displayed as an MGD rate.

Changing interval clears the entered minimum flow so it can be re-entered on the new basis.

03

Influent quality

Average concentrations

Enter available values. Concentrations use mg/L with the analyte basis shown beside each label.

Common design-basis parameters

Leave unavailable values blank

No mass load is calculated.

Canonical storage: °C. No mass load is calculated.

Average concentration basis

Period, location, and source notes
Additional parameters · VSS, orthophosphate-P, oil & grease, TDS, conductivity, custom

Optional average concentrations

Custom constituents

Up to five named concentrations. Custom rows do not feed built-in ratios.

04

Peak / variability

Optional peak concentration cases

Add a separate concentration record only when it is available for the matching maximum-day or peak-hour flow.

Maximum-day concentration record

Use a sample from the same 24-hour period as the maximum-day flow.

Period, location, and source notes

Maximum-day concentrations

Optional maximum-day analytes
Peak-hour concentration record

Use a sample from the same hour and location as the peak-hour flow.

Period, location, and source notes

Peak-hour concentrations

Optional peak-hour analytes
Advanced / Event basisOne bounded event or shock basisOptional · no recurrence or time-series modeling

Enter one declared event only. Event rate and integrated mass require event flow/concentration pairing; duration is required for integrated mass.

Optional · Available · Extends Wastewater Influent Basis

Wastewater Influent Basis — Acceptance Criteria Extension

Compare project-declared criteria with traceable influent cases. A comparison identifies a declared design or acceptance gap; it does not select a treatment process.

Primary Influent Basis ↑
This extension compares user- or project-declared acceptance criteria against traceable wastewater cases. It does not certify regulatory compliance, toxicity, treatability, or source acceptance.

ATLAS compares declared criteria. It does not determine which regulatory, utility, permit, or contractual limit applies to the project.

Comparison basis

Declare each observed case time basis

Must match the criterion

Sampling method, period, location, source, and point remain in the primary Influent Basis. Select the actual averaging or event context here; ATLAS will not infer it from a label or timestamp.

Unknown / not declared · unknown
Unknown / not declared · unknown
Unknown / not declared · unknown

Declared criteria

Project acceptance criteria

No project criterion is preloaded. Add limits and reference text supplied by the project or owner.

Comparison results

Declared acceptance criteria comparison

unavailable

A current accepted Influent Basis case is required. Editing the primary basis invalidates these comparison results until its new result is accepted.

此工程工具目前仅提供英文版本。

01

工程依据

方法

每个配对工况的水力和质量负荷数值根据已声明的流量与浓度计算,并将负荷统一为规范 SI 单位。

只有在该工况中明确配对流量和浓度时才报告实测峰值负荷;平均值保持情景仍属于估算。

假设

  • 流量系数和样品元数据由用户作为项目输入声明。
  • 缺失数据保持缺失;工具不会推断未配对的浓度或负荷。

范围 / 限制

  • 本依据不判定法规符合性、工艺可接受性、需氧量、药剂剂量、均衡池容积或下游设备尺寸。
02

工程路径

上游背景

  • 已声明的进水流量和样品数据 按项目声明输入流量、浓度、采样依据和来源元数据。

当前工具决策

  • 污水进水设计基础 建立可用于计算的水力与质量负荷依据,同时保留明确的工况配对关系。

下游工程步骤