Engineering Tool · Water Treatment

UV Disinfection Designer

Use entered UVT capacity reference points to screen reactor count, standby units, and operating power.

Municipal Drinking WaterStage 05 — Disinfection
Status
Available

01 · USER INPUT

Design basis and inputs

Unit system

APlant and design basis

Flow is the total assigned to the reactor bank. The design UVT must match an entered point unless the documented external source permits interpolation. Use the same UVT wavelength and optical path length as the reference data.

BUV dose and reference basis

The user-selected target dose must match the entered reference-dose value. Neither dose value is calculated by this tool.

CReactor configuration and power

Standby reactors are not assumed energized. Blank or zero per-reactor power keeps operating duty power unavailable.

DExternal source and interpolation basis

Leave this off for exact entered reference points. If enabled, document the source above and confirm it covers this reactor/model, target/reference dose, UVT basis, lamp/configuration, and operating envelope. ATLAS does not independently verify the source or interpolation rule.

Entered reactor performance/reference data

Enter two or more unique UVT points for one reactor at the entered reference dose. Rows can be entered in any order.

Reference pointUVT (%)Capacity per reactor(m3/h/reactor)Remove
Reference point 1
Reference point 2

Use UVT values at the same wavelength and optical path length as the entered external reference data; EPA UVDGM commonly uses 254 nm and 1 cm. No absorbance or path-length conversion is applied. Each UVT must be greater than 0% and no more than 100%. Each entered reference flow capacity must be positive. Duplicate UVT values are rejected.

Uses entered reactor performance/reference data. Dose is not derived from electrical power.

02 · CALCULATED RESULT

Engineering results

Enter a design basis and reactor performance/reference data, then calculate a screening result.

03 · REPORTING

Exports

01

Engineering Basis

Methodology

Sizes duty and standby reactor counts from entered external UVT/capacity reference points, using an exact point by default. Interpolation is allowed only when the documented external source authorizes it for the applicable reactor and operating envelope; there is no extrapolation or automatic regulatory dose credit.

At an exact design UVT match, capacity is taken from that exact entered reactor performance/reference point.

For an intermediate UVT, bounded linear interpolation is available only when the user confirms that the external validation/reference source permits this capacity relationship for the applicable reactor/model, target/reference dose, UVT basis, lamp/configuration basis, and operating envelope, and documents that source. This interpolation is user-authorized from entered external reference data; ATLAS does not independently validate it. No extrapolation is used.

EPA UV reactor validation is based on reactor-specific validated operating conditions. Dose/RED relationships with flow, UVT, lamp status/intensity, and other operating parameters depend on the reactor and validation method. ATLAS does not derive a generic UV dose-monitoring equation. Boundedness alone does not establish that linear interpolation is valid.

UVT values must use the same wavelength and optical path length as the entered external reference data; no absorbance or path-length conversion is applied.

Duty reactor count = ceiling(plant design flow / capacity per reactor from entered external reference data). Installed count = duty reactors + entered standby reactors.

Operating duty power = duty reactors x entered per-reactor electrical power. Standby reactors are not assumed energized.

The user-selected target dose must match the user-entered reference-dose value; neither dose value is calculated by this tool.

Scope / Limitations

  • An exact entered reference point is the default. Bounded linear interpolation is available only when the user documents that the external source authorizes it; the tool does not extrapolate or establish validated UV dose credit.
  • This is a screening calculation over user-entered reactor performance/reference data. The tool does not verify the external source or the entered data and does not establish regulatory UV dose credit.
  • Lamp power, flow, and UVT alone are not used to derive UV dose. The tool does not model reactor physics or CFD.
  • No theoretical fluence, RED, Validation Factor, pathogen dose requirement, organism-specific log inactivation, dose-monitoring equation, lamp/intensity physics, organism credit, manufacturer selection, or regulatory compliance logic is calculated.
  • Use the UVT wavelength and path length specified by the external source (EPA UVDGM examples commonly use 254 nm and 1 cm).
02

Engineering Path

Upstream Context

  • Targeted advanced-treatment basisOnly carry forward an adsorption or oxidation barrier when a named water-quality objective supports it.

Current Tool Decision

  • UV Disinfection DesignerUse entered UVT capacity reference points to screen reactor count, standby units, and operating power.

Downstream Engineering Step