方法
根据用户输入的外部 UVT/容量参考点计算运行及备用反应器数量,默认使用精确匹配点。只有当有记录的外部来源针对相应反应器和运行范围授权时才可插值;不外推,也不自动授予法规剂量抵扣。
At an exact design UVT match, capacity is taken from that exact entered reactor performance/reference point.
For an intermediate UVT, bounded linear interpolation is available only when the user confirms that the external validation/reference source permits this capacity relationship for the applicable reactor/model, target/reference dose, UVT basis, lamp/configuration basis, and operating envelope, and documents that source. This interpolation is user-authorized from entered external reference data; ATLAS does not independently validate it. No extrapolation is used.
EPA UV reactor validation is based on reactor-specific validated operating conditions. Dose/RED relationships with flow, UVT, lamp status/intensity, and other operating parameters depend on the reactor and validation method. ATLAS does not derive a generic UV dose-monitoring equation. Boundedness alone does not establish that linear interpolation is valid.
UVT values must use the same wavelength and optical path length as the entered external reference data; no absorbance or path-length conversion is applied.
Duty reactor count = ceiling(plant design flow / capacity per reactor from entered external reference data). Installed count = duty reactors + entered standby reactors.
Operating duty power = duty reactors x entered per-reactor electrical power. Standby reactors are not assumed energized.
The user-selected target dose must match the user-entered reference-dose value; neither dose value is calculated by this tool.